A laboratory centrifuge is an instrument that separates components of a sample by spinning it at high speed, using centrifugal force to separate particles or phases according to their density, size, and shape. Centrifuges are used across molecular biology, clinical diagnostics, chemistry, and pharmaceutical laboratories for tasks such as separating cells from plasma, pelleting DNA or protein precipitates, and clarifying solutions before further analysis.
What types of laboratory centrifuges are there?
- Microcentrifuges: compact benchtop units for small sample volumes, typically 0.2 mL to 2 mL tubes, commonly used in molecular biology
- Benchtop centrifuges: general-purpose units handling larger tube or bottle volumes, used for cell separation, clinical samples, and general lab workflows
- High-speed centrifuges: capable of generating higher RCF values for demanding separation tasks such as organelle isolation
- Ultracentrifuges: generate the highest rotational speeds and RCF values, used for separating very small particles such as viruses, ribosomes, or macromolecules
- Refrigerated centrifuges: maintain a controlled low temperature during operation, used for temperature-sensitive biological samples
The most suitable centrifuge depends on the required centrifugal force, sample volume, temperature control, and application.
How does a centrifuge work?
A centrifuge works by rotating a sample at high speed around a fixed axis. As the sample rotates, it experiences an apparent outward centrifugal force that causes denser particles to move away from the axis of rotation, while less dense components remain closer to the center. This separation occurs because centrifugal force accelerates sedimentation far beyond what gravity alone would achieve. It allows particles that would take hours or days to settle naturally to separate within minutes.
The sample is loaded into tubes or bottles placed in a rotor, which spins around a central motor shaft. As rotational speed increases, the force acting on the sample increases correspondingly, and particles migrate according to their size, shape, and density relative to the surrounding liquid.
What are the main components of a centrifuge?
- Rotor: holds the sample tubes or bottles and spins around the central axis, available in fixed-angle, swinging-bucket, and other configurations
- Motor: drives the rotor at controlled speeds, often up to tens of thousands of RPM depending on the centrifuge type
- Chamber and lid: encloses the rotor during operation for safety and, in refrigerated models, temperature control
- Control panel: allows the operator to set speed, RCF, run time, temperature, and acceleration or deceleration profiles
What is centrifugal force?
Centrifugal force is the apparent outward force experienced by a sample as it rotates in a centrifuge. It arises because the sample resists the continuous change in direction imposed by circular motion. As a result, particles move outward relative to the axis of rotation, with larger and denser particles generally sedimenting faster than smaller or less dense particles.
How is centrifugal force generated in a centrifuge?
Centrifugal force in a centrifuge is generated by the rotor spinning at high speed, with the magnitude of the force increasing with both the rotational speed and the distance from the axis of rotation. This is why the same rotational speed produces different forces at different points within the rotor, and why RCF, rather than RPM alone, is used to describe the actual separating force applied to a sample.
What is relative centrifugal force (RCF)?
Relative centrifugal force, commonly abbreviated RCF and expressed in multiples of gravitational force (× g), is a standardized measure of the force applied to a sample during centrifugation. RCF accounts for both the rotational speed and the radius of the rotor. This makes it a consistent value that can be compared across different centrifuges and rotor types, unlike RPM, which depends on the specific rotor’s dimensions.
What is RPM?
RPM, or revolutions per minute, is a measure of how many complete rotations the centrifuge rotor makes in one minute. It describes the rotational speed of the instrument itself, but because the actual force experienced by a sample depends on the rotor’s radius as well as its speed, RPM alone does not indicate the separating force applied, which is why RCF is used for reproducible protocols.
RCF vs RPM: what’s the difference?
RPM describes how fast the rotor is spinning, while RCF describes the relative centrifugal force (expressed as × g) experienced by the sample, taking both the rotational speed and the rotor radius into account. Two centrifuges set to the same RPM but fitted with rotors of different radii will generate different RCF values. This is why scientific protocols almost always specify RCF rather than RPM. Using RCF ensures that the same centrifugation conditions can be reproduced on different centrifuges and rotor types.
- RPM: the rotational speed of the rotor, measured in revolutions per minute
- RCF: the relative centrifugal force (× g) experienced by the sample, determined by both rotor speed and rotor radius
- Conversion: converting between RPM and RCF requires knowing the rotor radius
Why is rotor balancing important?
Rotor balancing ensures that the mass loaded into the rotor is distributed evenly around the axis of rotation, preventing vibration, mechanical stress, and potential damage to the centrifuge during operation. An unbalanced rotor, caused by unevenly filled or unevenly paired tubes. It generates a wobbling motion at high speed that can damage the motor bearings, degrade separation quality, and in severe cases cause the rotor to fail during a run.
- Samples should be balanced according to the rotor manufacturer’s instructions, typically by placing tubes of equal mass opposite one another in symmetrical positions
- An odd number of samples requires a balance tube filled with an equivalent mass to complete the pairing
- Even minor mass differences become significant at high RPM, since imbalance forces increase with the square of rotational speed
How to prevent microcentrifuge tube lids from breaking during centrifugation?
What can a centrifuge separate?
A centrifuge separates components within a liquid sample based on differences in size, density, and sedimentation behavior. It uses centrifugal force to accelerate the natural settling process that would otherwise occur much more slowly under gravity.
The range of materials a centrifuge can separate extends from whole cells and cellular organelles to proteins, nucleic acids, viruses, and other macromolecular complexes, depending on the centrifugal force applied, the rotor used, and the duration of centrifugation.
- Suspended particles: solid particles dispersed within a liquid, separated from the surrounding fluid as they move outward under centrifugal force
- Cells: whole cells, such as blood cells or cultured cells, pelleted from a surrounding medium or plasma based on their size and density
- Organelles: subcellular structures such as nuclei, mitochondria, lysosomes, or ribosomes, isolated by differential or density gradient centrifugation using progressively higher centrifugal forces
- Proteins: concentrated or isolated from solution, often following precipitation or during purification workflows
- Nucleic acids: DNA and RNA pelleted from solution following precipitation steps, commonly after alcohol precipitation using high-speed microcentrifuges, although ultracentrifuges are used for specialized nucleic acid purification techniques
- Precipitates: solid material formed through a chemical or biological reaction, separated from the remaining liquid phase
- Immiscible liquid phases: liquids that do not mix, such as an aqueous and an organic phase, separated into distinct layers based on differing densities
The exact separation achieved depends on the centrifugal force, centrifugation time, rotor type, and the physical properties of the particles being separated. In general, larger and denser particles sediment more readily than smaller or less dense particles, although the density and viscosity of the surrounding liquid also influence separation efficiency.
| Term | Meaning |
| RPM | Rotor speed (revolutions per minute) |
| RCF | Centrifugal force applied to the sample (× g) |
| Rotor | Holds and spins the sample tubes |
| Centrifugal force | Drives particle separation during centrifugation |
Explore our centrifuges here