At LabSPX, we are committed to bringing innovative and efficient solutions to laboratories. Our Smart Lab Solutions are designed to streamline processes, enhance accuracy, and boost productivity.
| Specification | More info |
|---|---|
| 3’ & 4’ Logic Class II | Nominal width: 91,44 cm or 121,92 cm |
| 5’ & 6’ Logic Class II, Type A2 | Nominal width: 152,40 cm or 182,88 cm |
| 8' Logic Class II, Type A2 |
These biological safety cabinets provide robust protection for personnel, products, and the environment against hazardous particulates. They include agents requiring BSL 1-4 containment. These cabinets are ideal for handling antineoplastic drugs, genetic material, and other dangerous airborne particles. Every model meets the highest standards of safety and performance and is NSF-listed.
Designed for maximum versatility, Logic BSCs exhaust HEPA-filtered air directly into the lab or into an external exhaust system via the optional Ventus II Canopy Connection. Logic BSCs are suitable for applications involving trace amounts of volatile toxic chemicals and radionuclides when they connect to a canopy.
Room air is drawn in through the inlet grille. Beneath the work surface, the plenum contains a mix of unfiltered room air and air that has passed through the work area. This contaminated air is pulled by the ECM blower through the rear plenum of the Logic BSC.
Approximately 70% of it recirculates through the supply HEPA filter and back over the work area, maintaining an ISO Class 5 environment. The remaining contaminated air expels into the environment via the high-efficiency exhaust HEPA filter.
Long-life DC Electronically Commutated Motor (ECM)
Constant Airflow Profile™ (CAP) airflow monitoring system
Easy-clean top cover designed to promote even exhaust airflow
Intrinsically-safe negative pressure design
Fully scannable HEPA filters with 99.99+% efficiency for both supply and exhaust; optional ULPA filters (99.999%) or H14 HEPA filters also available
Bright, glare-free LED lighting up to 180 foot-candles (1937 lux), positioned outside the contaminated work area
Curved stainless steel inlet grille with waterfall design and Reserve-Air™ secondary airflow slots
Air-Wave™ Entry System at the access opening enhances containment
Contain-Air™ Negative Pressure Channel at the top of the sash improves containment
Approximately 70% air recirculation
Noise level <60 dB (4 ft 10" model)
NSF/ANSI Standard 49 listed
NSF/ANSI 49 compliant (Cell Logic models)
ISO Class 5 (Grade A) per ISO 14644-1
UL Standard 61010-1
CAN/CSA 22.2 No. 61010-1
CE/UKCA Mark (230V models)
ADA-compliant