{"id":2860,"date":"2026-01-29T14:50:44","date_gmt":"2026-01-29T12:50:44","guid":{"rendered":"https:\/\/labspx.com\/?p=2860"},"modified":"2026-08-21T11:16:16","modified_gmt":"2026-08-21T09:16:16","slug":"sterilisation-auf-der-grundlage-ihrer-beladungsart","status":"publish","type":"post","link":"https:\/\/labspx.com\/de\/sterilization-based-on-your-load-type\/","title":{"rendered":"Sterilisation je nach Beladungsart"},"content":{"rendered":"<div class=\"product\"><div class=\"product\">\t\t<div data-elementor-type=\"wp-post\" data-elementor-id=\"2860\" class=\"elementor elementor-2860\" data-elementor-post-type=\"post\">\n\t\t\t\t<div class=\"elementor-element elementor-element-f7c59ab e-flex e-con-boxed e-con e-parent\" data-id=\"f7c59ab\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;jet_parallax_layout_list&quot;:[]}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-fcdbeae elementor-widget elementor-widget-heading\" data-id=\"fcdbeae\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Which sterilization method fits your load type?<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-c2fee80 elementor-widget elementor-widget-text-editor\" data-id=\"c2fee80\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\">Choosing the right sterilization process starts with understanding your load type. Laboratory waste, liquids, glassware, porous materials, and high-risk biological loads all behave differently during sterilization, and therefore require specific cycles, temperatures, and handling methods. This guide covers the most common load types and what to consider for each.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-2e82c22 elementor-widget__width-initial elementor--h-position-center elementor--v-position-middle elementor-arrows-position-inside elementor-pagination-position-inside elementor-widget elementor-widget-slides\" data-id=\"2e82c22\" data-element_type=\"widget\" data-e-type=\"widget\" data-settings=\"{&quot;navigation&quot;:&quot;both&quot;,&quot;autoplay&quot;:&quot;yes&quot;,&quot;pause_on_hover&quot;:&quot;yes&quot;,&quot;pause_on_interaction&quot;:&quot;yes&quot;,&quot;autoplay_speed&quot;:5000,&quot;infinite&quot;:&quot;yes&quot;,&quot;transition&quot;:&quot;slide&quot;,&quot;transition_speed&quot;:500}\" data-widget_type=\"slides.default\">\n\t\t\t\t\t\t\t\t\t\t<div class=\"elementor-slides-wrapper elementor-main-swiper swiper\" role=\"region\" aria-roledescription=\"carousel\" aria-label=\"Load types \" dir=\"ltr\" data-animation=\"fadeInUp\">\n\t\t\t\t<div class=\"swiper-wrapper elementor-slides\">\n\t\t\t\t\t\t\t\t\t\t<div class=\"elementor-repeater-item-dbb543a swiper-slide\" role=\"group\" aria-roledescription=\"slide\"><div class=\"swiper-slide-bg\" role=\"img\" aria-label=\"LinkedIn LabSPX (26)\"><\/div><div class=\"swiper-slide-inner\" ><div class=\"swiper-slide-contents\"><div class=\"elementor-slide-heading\">Liquids <\/div><div class=\"elementor-slide-description\">Solutions or chemicals used in laboratory environments, such as growth media<\/div><a href=\"#liquidloads\" class=\"elementor-button elementor-slide-button elementor-size-sm\">Read more <\/a><\/div><\/div><\/div><div class=\"elementor-repeater-item-9f2d2a1 swiper-slide\" role=\"group\" aria-roledescription=\"slide\"><div class=\"swiper-slide-bg\" role=\"img\" aria-label=\"LinkedIn LabSPX (27)\"><\/div><div class=\"swiper-slide-inner\" ><div class=\"swiper-slide-contents\"><div class=\"elementor-slide-heading\">Waste <\/div><div class=\"elementor-slide-description\">Microbiological laboratory waste, clinical samples such as blood, tissue, and other biological materials<\/div><a href=\"#wasteload\" class=\"elementor-button elementor-slide-button elementor-size-sm\">Read more <\/a><\/div><\/div><\/div><div class=\"elementor-repeater-item-0d4b0ce swiper-slide\" role=\"group\" aria-roledescription=\"slide\"><div class=\"swiper-slide-bg\" role=\"img\" aria-label=\"LinkedIn LabSPX (28)\"><\/div><div class=\"swiper-slide-inner\" ><div class=\"swiper-slide-contents\"><div class=\"elementor-slide-heading\">Glassware <\/div><div class=\"elementor-slide-description\">Conical and volumetric flasks, beakers, test tubes, graduated cylinders, watch glasses, and similar items<\/div><a href=\"#glasswareloads\" class=\"elementor-button elementor-slide-button elementor-size-sm\">Read more <\/a><\/div><\/div><\/div><div class=\"elementor-repeater-item-0041668 swiper-slide\" role=\"group\" aria-roledescription=\"slide\"><div class=\"swiper-slide-bg\" role=\"img\" aria-label=\"LinkedIn LabSPX (29)\"><\/div><div class=\"swiper-slide-inner\" ><div class=\"swiper-slide-contents\"><div class=\"elementor-slide-heading\">Porous loads <\/div><div class=\"elementor-slide-description\">Gowns, instrument packs, and other reusable items<\/div><a href=\"#porousloads\" class=\"elementor-button elementor-slide-button elementor-size-sm\">Read more <\/a><\/div><\/div><\/div><div class=\"elementor-repeater-item-9c44f14 swiper-slide\" role=\"group\" aria-roledescription=\"slide\"><div class=\"swiper-slide-bg\" role=\"img\" aria-label=\"LinkedIn LabSPX (30)\"><\/div><div class=\"swiper-slide-inner\" ><div class=\"swiper-slide-contents\"><div class=\"elementor-slide-heading\">Hazardous waste \t<\/div><div class=\"elementor-slide-description\">Harmful human pathogens, viruses, and bacteria that pose serious health and safety risks<\/div><a href=\"#hazardouswaste\" class=\"elementor-button elementor-slide-button elementor-size-sm\">Read more<\/a><\/div><\/div><\/div>\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<div class=\"elementor-swiper-button elementor-swiper-button-prev\" role=\"button\" tabindex=\"0\" aria-label=\"Vorheriger Slide\">\n\t\t\t\t\t\t\t<i aria-hidden=\"true\" class=\"eicon-chevron-left\"><\/i>\t\t\t\t\t\t<\/div>\n\t\t\t\t\t\t<div class=\"elementor-swiper-button elementor-swiper-button-next\" role=\"button\" tabindex=\"0\" aria-label=\"N\u00e4chster Slide\">\n\t\t\t\t\t\t\t<i aria-hidden=\"true\" class=\"eicon-chevron-right\"><\/i>\t\t\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<div class=\"swiper-pagination\"><\/div>\n\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-1902cb9 elementor-widget elementor-widget-spacer\" data-id=\"1902cb9\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"spacer.default\">\n\t\t\t\t\t\t\t<div class=\"elementor-spacer\">\n\t\t\t<div class=\"elementor-spacer-inner\"><\/div>\n\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-86400a2 elementor-widget elementor-widget-menu-anchor\" data-id=\"86400a2\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"menu-anchor.default\">\n\t\t\t\t\t\t\t<div class=\"elementor-menu-anchor\" id=\"liquidloads\"><\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-817466b elementor-widget elementor-widget-heading\" data-id=\"817466b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Liquids <\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-d6fa596 elementor-widget elementor-widget-text-editor\" data-id=\"d6fa596\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<h3>What is a fluid load?<\/h3><p>Fluid or liquid loads typically consist of solutions or chemicals used in laboratory environments, such as growth media. They can include any non-solid material that requires sterilization. Growth or culture media may be solid, liquid, or semi-solid and are designed to support the growth of microorganisms or cells under controlled conditions. Different media are used for different cell types and must be sterilized before use, usually in an autoclave.<\/p><h3>What are the sterilization parameters for fluid loads?\u00a0<\/h3><p>Many media are sterilized at 121\u00b0C, with the required exposure time depending on factors such as the volume and container geometry. Larger volumes generally require longer exposure to reach the required temperature throughout the liquid. Autoclaves used for media sterilization should therefore support different cycle parameters and controlled exhaust or cooling phases to reduce the risk of boil-over during depressurization.<\/p><h3>What type of fluid discard require sterilization?<\/h3><p>Fluid discard loads include waste liquids that require sterilization before disposal. Common examples include:<\/p><ul><li>Used or expired culture media (such as nutrient broth)<\/li><li>Reagents<\/li><li>Liquid specimens<\/li><li>Cleaning solutions<\/li><li>Biological waste<\/li><\/ul><h3>How are sealed fluids sterilized?<\/h3><p>Some fluid loads require sterilization in sealed containers. In these cases, air removal by air purging or freesteaming may be sufficient, depending on the load and autoclave cycle. Prolonged freesteaming is generally unnecessary. Higher temperatures than 121\u00b0C may also be used to shorten sterilization times, while controlled cooling helps prevent problems caused by rapid depressurization.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-4af8df2 elementor-widget elementor-widget-menu-anchor\" data-id=\"4af8df2\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"menu-anchor.default\">\n\t\t\t\t\t\t\t<div class=\"elementor-menu-anchor\" id=\"wasteload\"><\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-c0bf650 elementor-widget elementor-widget-heading\" data-id=\"c0bf650\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Waste <\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-d639542 elementor-widget elementor-widget-menu-anchor\" data-id=\"d639542\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"menu-anchor.default\">\n\t\t\t\t\t\t\t<div class=\"elementor-menu-anchor\" id=\"glasswareloads\"><\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-62ea8c3 elementor-widget elementor-widget-text-editor\" data-id=\"62ea8c3\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<h3>What is a mixed discard load?<\/h3><p>A mixed discard load consists of contaminated materials of different types and forms that must be sterilized before disposal. This can include microbiological laboratory waste as well as clinical materials such as blood, tissue, and other biological waste. Because these loads contain a variety of materials, they can present challenges for effective steam penetration.<\/p><p>Typical mixed discard loads may contain a combination of items, including:<\/p><ul><li>Plastic bags<\/li><li>Containers<\/li><li>Fabrics<\/li><li>Gloves<\/li><li>Paper towels<\/li><li>Pipettes<\/li><li>Culture plates<\/li><\/ul><h3>Why is sterilizing mixed discard loads tricky?<\/h3><p class=\"isSelectedEnd\">The main challenge with mixed discard loads is the presence of small pockets of trapped air, which can prevent effective steam penetration. These loads are often placed in plastic bags that may include containers that can melt or collapse before sterilization is complete, further increasing the risk of air pockets.<\/p><p class=\"isSelectedEnd\">For this reason, an advanced vacuum system is recommended to improve air removal. It is also essential not to overfill the autoclave chamber, as overloading can prevent consistent steam penetration.<\/p><h3>What is multi-point validation and why 12 points?<\/h3><p class=\"isSelectedEnd\">Multi-point (12-pen) validation uses 12 calibrated thermocouple probes distributed through the load during a heat distribution study. The probes are positioned at different locations within the load to identify areas where the required sterilization conditions may be more difficult to achieve.<\/p><p class=\"isSelectedEnd\">Using multiple measurement points helps verify that the required temperature is reached throughout the load and can help identify potential cold spots. The exact validation procedure depends on the autoclave and load configuration.<\/p><p>For high-risk waste, autoclave options compliant with Category III (BSL-3) requirements are available, including HEPA filtration and vacuum systems. Using dedicated discard containers is also advised to contain spills and keep the autoclave chamber clean.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-9599743 elementor-widget elementor-widget-heading\" data-id=\"9599743\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Glassware <\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-5f3cfdf elementor-widget elementor-widget-text-editor\" data-id=\"5f3cfdf\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<h3>Which glassware can be autoclaved?<\/h3><p>Autoclaving scientific glassware ensures effective surface sterilization.<\/p><p>A wide range of glass items are routinely sterilized in laboratory environments, including:<\/p><ul><li>Conical and volumetric flasks,<\/li><li>Beakers<\/li><li>Test tubes<\/li><li>Graduated cylinders<\/li><li>Watch glasses<\/li><\/ul><p>Borosilicate or quartz glassware is generally recommended, as these materials are better able to withstand the high temperatures and pressures encountered during autoclave cycles.<\/p><h3>What are unwrapped instruments?<\/h3><p>Unwrapped instruments typically include items used in medical, dental, veterinary, beauty, and ophthalmic procedures, as well as selected laboratory equipment. In some cases, larger items such as laboratory apparatus or metal cages must also be sterilized and are usually processed as unwrapped instruments.<\/p><h3>What are the challenges of sterilizing glassware and unwrapped instruments?<\/h3><p class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\">Sterilizing glassware requires careful handling to prevent breakage or shattering. Empty glassware should never be sealed when using high-vacuum drying, and proper loading and unloading practices are essential to avoid damage, overcrowding, or scalding risk.<\/p><p class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\">Post-cycle drying is beneficial for all instrument loads. Unwrapped instruments are dried by heating the surrounding air, while glassware may require specialized drying procedures. For small benchtop units, post-vacuum systems improve drying efficiency; larger units should use a jacketed pressure vessel for optimal results.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-1a02240 elementor-widget elementor-widget-menu-anchor\" data-id=\"1a02240\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"menu-anchor.default\">\n\t\t\t\t\t\t\t<div class=\"elementor-menu-anchor\" id=\"porousloads\"><\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-3052039 elementor-widget elementor-widget-heading\" data-id=\"3052039\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Porous loads <\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-bab0301 elementor-widget elementor-widget-text-editor\" data-id=\"bab0301\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<h3>What types of porous loads can be sterilized in an autoclave?<\/h3><p>Autoclaves can sterilize a wide variety of fabrics and textiles. In hospitals, this commonly includes gowns, instrument packs, and other reusable items. Veterinary practices may use autoclaves for animal bedding and instruments.<\/p><p class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\">Central Sterile Service Departments (CSSDs) typically use a combination of pouches and wrapping depending on the size and type of instruments. Small instruments are usually placed in pouches, while larger items such as trays and pans are wrapped. Surgical packs and wraps are commonly sealed with autoclave tape, which changes color when the correct sterilization temperature is reached, confirming successful sterilization. Standard masking tape cannot withstand autoclave conditions and should never be used as a substitute.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-f151851 elementor-widget elementor-widget-menu-anchor\" data-id=\"f151851\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"menu-anchor.default\">\n\t\t\t\t\t\t\t<div class=\"elementor-menu-anchor\" id=\"hazardouswaste\"><\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-4d7bc7c elementor-widget elementor-widget-heading\" data-id=\"4d7bc7c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Hazardous waste <\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-5a067c4 elementor-widget elementor-widget-text-editor\" data-id=\"5a067c4\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<h3>What makes BSL-3 waste sterilization different?<\/h3><p class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\">Biosafety Level 3 (BSL-3) facilities handle highly regulated work with harmful human pathogens, viruses, and bacteria that pose serious health and safety risks. Examples of microbes handled in BSL-3 laboratories include <em>Clostridium botulinum<\/em> (botulism), yellow fever virus, and <em>Mycobacterium tuberculosis<\/em>.<\/p><p class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\">Waste from these environments must be effectively sterilized before disposal. In some cases, a double-door or pass-through autoclave is used, with the loading side separated from the unloading side by a containment wall. This configuration helps prevent sterilized material from being recontaminated when it is removed from the autoclave.<\/p><h3>What HEPA filtration is used for BSL-3 autoclaves?<\/h3><p class=\"isSelectedEnd\">BSL-3 autoclave systems can incorporate HEPA filtration and other containment features to help prevent potentially harmful biological material from being released from the system. The specific filtration requirements depend on the facility, autoclave design, and applicable containment requirements.<\/p><p>BSL-3 facilities may also require effluent retention systems and bacteriological HEPA filters on exhausts to help prevent harmful pathogens from being released into the environment.<\/p><h3>Why is sterilizing prions and other resistant microbes challenging?<\/h3><p class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\">Most microorganisms are killed above 80 \u00b0C, but some require higher temperatures and longer exposure times. Prions are a notable example because they are considerably more resistant to conventional sterilization processes.<\/p><p class=\"isSelectedEnd\">Prion-contaminated materials therefore require specialized sterilization procedures, which may involve extended autoclave cycles and, depending on the application and applicable guidance, chemical pretreatment. The appropriate procedure should always be determined according to the relevant biosafety and sterilization requirements.<\/p><p>A heated jacket is often used in hazardous waste applications to support even temperature distribution throughout the chamber. Custom cycle settings may be necessary to ensure that hazardous material is thoroughly and safely sterilized.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-4f74c4b elementor-widget elementor-widget-heading\" data-id=\"4f74c4b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Key takeaways<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-50880b5 elementor-widget elementor-widget-text-editor\" data-id=\"50880b5\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<h3 class=\"text-text-100 mt-3 -mb-1 text-[1.125rem] font-bold\">Matching your load type to the right autoclave cycle<\/h3><p class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\">Different load types require fundamentally different sterilization approaches:<\/p><ul class=\"[li_&amp;]:mb-0 [li_&amp;]:mt-1 [li_&amp;]:gap-1 [&amp;:not(:last-child)_ul]:pb-1 [&amp;:not(:last-child)_ol]:pb-1 list-disc flex flex-col gap-1 pl-8 mb-3\"><li class=\"whitespace-normal break-words pl-2\"><strong>Liquid loads<\/strong> require controlled temperatures, appropriate cycle parameters, and short cooling times to preserve product quality.<\/li><li class=\"whitespace-normal break-words pl-2\"><strong>Mixed discard loads<\/strong> benefit from advanced vacuum systems, dedicated containers, and multi-point validation to ensure steam penetration.<\/li><li class=\"whitespace-normal break-words pl-2\"><strong>Glassware and unwrapped instruments<\/strong> need careful loading practices and post-cycle drying suited to the material type.<\/li><li class=\"whitespace-normal break-words pl-2\"><strong>Porous loads<\/strong> such as fabrics and instrument packs require proper wrapping and validated autoclave tape.<\/li><li class=\"whitespace-normal break-words pl-2\"><strong>High-risk and BSL-3 waste<\/strong> demands specialized equipment including pass-through autoclaves, HEPA filtration, and custom cycle settings.<\/li><\/ul><p class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\">Understanding your load type is the foundation of an effective, safe sterilization process, and the starting point for selecting the right autoclave configuration.<\/p><table><thead><tr><th scope=\"col\">Load type<\/th><th scope=\"col\">Typical temperature<\/th><th scope=\"col\">Typical time<\/th><th scope=\"col\">Key equipment feature<\/th><\/tr><\/thead><tbody><tr><td>Liquids<\/td><td>121\u00b0C<\/td><td>15 to 30 min<\/td><td>Slow exhaust, controlled cooling<\/td><\/tr><tr><td>Mixed discard<\/td><td>121 to 134\u00b0C<\/td><td>Varies by load<\/td><td>Advanced vacuum, 12-point validation<\/td><\/tr><tr><td>Unwrapped instruments (IUSS)<\/td><td>132 to 135\u00b0C<\/td><td>3 to 10 min<\/td><td>Direct steam contact, no packaging<\/td><\/tr><tr><td>Porous loads<\/td><td>121 to 134\u00b0C<\/td><td>Per wrap type<\/td><td>Validated autoclave tape<\/td><\/tr><tr><td>BSL-3 waste<\/td><td>121 to 134\u00b0C<\/td><td>Up to 1 hr<\/td><td>Pass-through design, HEPA \u226599.97% at 0.3 \u00b5m<\/td><\/tr><tr><td>Prion-contaminated<\/td><td>121 to 134\u00b0C<\/td><td>18 min to 1 hr<\/td><td>Chemical pretreatment, extended cycle<\/td><\/tr><\/tbody><\/table>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-a4f19b5 elementor-widget elementor-widget-spacer\" data-id=\"a4f19b5\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"spacer.default\">\n\t\t\t\t\t\t\t<div class=\"elementor-spacer\">\n\t\t\t<div class=\"elementor-spacer-inner\"><\/div>\n\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-2965035 elementor-widget elementor-widget-heading\" data-id=\"2965035\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Let's get in touch<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-34f545c elementor-button-align-stretch elementor-widget elementor-widget-form\" data-id=\"34f545c\" data-element_type=\"widget\" data-e-type=\"widget\" data-settings=\"{&quot;step_next_label&quot;:&quot;Next&quot;,&quot;step_previous_label&quot;:&quot;Previous&quot;,&quot;button_width&quot;:&quot;100&quot;,&quot;step_type&quot;:&quot;number_text&quot;,&quot;step_icon_shape&quot;:&quot;circle&quot;}\" data-widget_type=\"form.default\">\n\t\t\t\t\t\t\t<form class=\"elementor-form\" method=\"post\" name=\"New Form\" aria-label=\"New Form\">\n\t\t\t<input type=\"hidden\" name=\"post_id\" value=\"2860\"\/>\n\t\t\t<input type=\"hidden\" name=\"form_id\" value=\"34f545c\"\/>\n\t\t\t<input type=\"hidden\" name=\"referer_title\" value=\"LabSPX\" \/>\n\n\t\t\t\n\t\t\t<div class=\"elementor-form-fields-wrapper elementor-labels-above\">\n\t\t\t\t\t\t\t\t<div class=\"elementor-field-type-text elementor-field-group elementor-column elementor-field-group-name elementor-col-100\">\n\t\t\t\t\t\t\t\t\t\t\t\t<label for=\"form-field-name\" class=\"elementor-field-label\">\n\t\t\t\t\t\t\t\tName\t\t\t\t\t\t\t<\/label>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t<input size=\"1\" type=\"text\" name=\"form_fields[name]\" id=\"form-field-name\" class=\"elementor-field elementor-size-sm  elementor-field-textual\" placeholder=\"Name\">\n\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t<div class=\"elementor-field-type-email elementor-field-group elementor-column elementor-field-group-email elementor-col-100 elementor-field-required\">\n\t\t\t\t\t\t\t\t\t\t\t\t<label for=\"form-field-email\" class=\"elementor-field-label\">\n\t\t\t\t\t\t\t\tEmail\t\t\t\t\t\t\t<\/label>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t<input size=\"1\" type=\"email\" name=\"form_fields[email]\" id=\"form-field-email\" class=\"elementor-field elementor-size-sm  elementor-field-textual\" placeholder=\"Email\" required=\"required\">\n\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t<div class=\"elementor-field-type-textarea elementor-field-group elementor-column elementor-field-group-message elementor-col-100\">\n\t\t\t\t\t\t\t\t\t\t\t\t<label for=\"form-field-message\" class=\"elementor-field-label\">\n\t\t\t\t\t\t\t\tMessage\t\t\t\t\t\t\t<\/label>\n\t\t\t\t\t\t<textarea class=\"elementor-field-textual elementor-field  elementor-size-sm\" name=\"form_fields[message]\" id=\"form-field-message\" rows=\"4\" placeholder=\"Message\"><\/textarea>\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t<div class=\"elementor-field-group elementor-column elementor-field-type-submit elementor-col-100 e-form__buttons\">\n\t\t\t\t\t<button class=\"elementor-button elementor-size-sm\" type=\"submit\">\n\t\t\t\t\t\t<span class=\"elementor-button-content-wrapper\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-button-text\">Send<\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t\t<\/span>\n\t\t\t\t\t<\/button>\n\t\t\t\t<\/div>\n\t\t\t<\/div>\n\t\t<\/form>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-c2b651a elementor-widget elementor-widget-spacer\" data-id=\"c2b651a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"spacer.default\">\n\t\t\t\t\t\t\t<div class=\"elementor-spacer\">\n\t\t\t<div class=\"elementor-spacer-inner\"><\/div>\n\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-28d9e92 elementor-widget elementor-widget-heading\" data-id=\"28d9e92\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">FAQ<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b772a5e elementor-widget elementor-widget-n-accordion\" data-id=\"b772a5e\" data-element_type=\"widget\" data-e-type=\"widget\" data-settings=\"{&quot;default_state&quot;:&quot;expanded&quot;,&quot;max_items_expended&quot;:&quot;one&quot;,&quot;n_accordion_animation_duration&quot;:{&quot;unit&quot;:&quot;ms&quot;,&quot;size&quot;:400,&quot;sizes&quot;:[]}}\" data-widget_type=\"nested-accordion.default\">\n\t\t\t\t\t\t\t<div class=\"e-n-accordion\" aria-label=\"Accordion. Open links with Enter or Space, close with Escape, and navigate with Arrow Keys\">\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-1920\" class=\"e-n-accordion-item\" open>\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"1\" tabindex=\"0\" aria-expanded=\"true\" aria-controls=\"e-n-accordion-item-1920\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> What is a fluid load? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><i aria-hidden=\"true\" class=\"fas fa-minus\"><\/i><\/span>\n\t\t\t<span class='e-closed'><i aria-hidden=\"true\" class=\"fas fa-plus\"><\/i><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-1920\" class=\"elementor-element elementor-element-b500385 e-con-full e-flex e-con e-child\" data-id=\"b500385\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;jet_parallax_layout_list&quot;:[]}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-b6669ae elementor-widget elementor-widget-text-editor\" data-id=\"b6669ae\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p>A fluid load consists of liquids used in laboratory environments, such as growth media, solutions, or chemicals, that require sterilization. Any non\u2011solid material that must be sterilized before use is considered a fluid load.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-1921\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"2\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-1921\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Why do sterilization parameters vary for fluid loads? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><i aria-hidden=\"true\" class=\"fas fa-minus\"><\/i><\/span>\n\t\t\t<span class='e-closed'><i aria-hidden=\"true\" class=\"fas fa-plus\"><\/i><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-1921\" class=\"elementor-element elementor-element-5faca54 e-con-full e-flex e-con e-child\" data-id=\"5faca54\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;jet_parallax_layout_list&quot;:[]}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-b668b2a elementor-widget elementor-widget-text-editor\" data-id=\"b668b2a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p>Different media types require different temperatures or exposure times. While many are sterilized at 121\u202f\u00b0C for 15 minutes, others need different cycle parameters, so autoclaves must support a wide temperature range.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-1922\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"3\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-1922\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> What types of fluid discard require sterilization? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><i aria-hidden=\"true\" class=\"fas fa-minus\"><\/i><\/span>\n\t\t\t<span class='e-closed'><i aria-hidden=\"true\" class=\"fas fa-plus\"><\/i><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-1922\" class=\"elementor-element elementor-element-e654cf8 e-con-full e-flex e-con e-child\" data-id=\"e654cf8\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;jet_parallax_layout_list&quot;:[]}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-407d571 elementor-widget elementor-widget-text-editor\" data-id=\"407d571\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<div>Typical fluid discard includes used culture media, reagents, liquid specimens, cleaning solutions, and biological waste.<\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-1923\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"4\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-1923\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> How are sealed fluids sterilized? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><i aria-hidden=\"true\" class=\"fas fa-minus\"><\/i><\/span>\n\t\t\t<span class='e-closed'><i aria-hidden=\"true\" class=\"fas fa-plus\"><\/i><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-1923\" class=\"elementor-element elementor-element-d755bcb e-flex e-con-boxed e-con e-child\" data-id=\"d755bcb\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;jet_parallax_layout_list&quot;:[]}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-12179da elementor-widget elementor-widget-text-editor\" data-id=\"12179da\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p>Sealed fluids are sterilized using air purging (freesteaming). Prolonged freesteaming is usually unnecessary. Higher temperatures than 121\u202f\u00b0C can shorten sterilization times, and cooling should be kept as short as possible to maintain product quality.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-1924\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"5\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-1924\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Why is sterilizing mixed discard loads challenging? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><i aria-hidden=\"true\" class=\"fas fa-minus\"><\/i><\/span>\n\t\t\t<span class='e-closed'><i aria-hidden=\"true\" class=\"fas fa-plus\"><\/i><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-1924\" class=\"elementor-element elementor-element-ece3a73 e-flex e-con-boxed e-con e-child\" data-id=\"ece3a73\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;jet_parallax_layout_list&quot;:[]}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-c0d9d8b elementor-widget elementor-widget-text-editor\" data-id=\"c0d9d8b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p>Because these loads often contain bags, plastics, and containers that trap air. This prevents effective steam penetration. Items may melt or collapse during the cycle, increasing the risk of air pockets.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-1925\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"6\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-1925\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Are special autoclaves needed for high\u2011risk waste <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><i aria-hidden=\"true\" class=\"fas fa-minus\"><\/i><\/span>\n\t\t\t<span class='e-closed'><i aria-hidden=\"true\" class=\"fas fa-plus\"><\/i><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-1925\" class=\"elementor-element elementor-element-e02dca7 e-flex e-con-boxed e-con e-child\" data-id=\"e02dca7\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;jet_parallax_layout_list&quot;:[]}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-b09b86f elementor-widget elementor-widget-text-editor\" data-id=\"b09b86f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p>Yes. For BSL\u20113 applications, autoclaves with HEPA filtration, vacuum systems, or Category III compliance are recommended.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-1926\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"7\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-1926\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Which types of glassware can be autoclaved? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><i aria-hidden=\"true\" class=\"fas fa-minus\"><\/i><\/span>\n\t\t\t<span class='e-closed'><i aria-hidden=\"true\" class=\"fas fa-plus\"><\/i><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-1926\" class=\"elementor-element elementor-element-96393b4 e-flex e-con-boxed e-con e-child\" data-id=\"96393b4\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;jet_parallax_layout_list&quot;:[]}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-fcbd6c3 elementor-widget elementor-widget-text-editor\" data-id=\"fcbd6c3\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p>Common autoclaved glassware includes flasks, beakers, test tubes, cylinders, and watch glasses. Borosilicate and quartz glassware are recommended because they tolerate high temperatures and pressure.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-1927\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"8\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-1927\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> How are glassware and instruments dried after sterilization? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><i aria-hidden=\"true\" class=\"fas fa-minus\"><\/i><\/span>\n\t\t\t<span class='e-closed'><i aria-hidden=\"true\" class=\"fas fa-plus\"><\/i><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-1927\" class=\"elementor-element elementor-element-438a64c e-flex e-con-boxed e-con e-child\" data-id=\"438a64c\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;jet_parallax_layout_list&quot;:[]}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-4f772c5 elementor-widget elementor-widget-text-editor\" data-id=\"4f772c5\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p>Unwrapped instruments dry through heated air. Glassware may require specialized drying or post\u2011vacuum systems (benchtop units) or jacketed vessels (large autoclaves).<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-1928\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"9\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-1928\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> What porous materials can be sterilized in an autoclave? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><i aria-hidden=\"true\" class=\"fas fa-minus\"><\/i><\/span>\n\t\t\t<span class='e-closed'><i aria-hidden=\"true\" class=\"fas fa-plus\"><\/i><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-1928\" class=\"elementor-element elementor-element-b0cac3d e-flex e-con-boxed e-con e-child\" data-id=\"b0cac3d\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;jet_parallax_layout_list&quot;:[]}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-c6726ed elementor-widget elementor-widget-text-editor\" data-id=\"c6726ed\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p>Textiles such as gowns, wraps, bedding, and reusable instrument packs.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-1929\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"10\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-1929\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Why is autoclave tape important? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><i aria-hidden=\"true\" class=\"fas fa-minus\"><\/i><\/span>\n\t\t\t<span class='e-closed'><i aria-hidden=\"true\" class=\"fas fa-plus\"><\/i><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-1929\" class=\"elementor-element elementor-element-aecaec9 e-flex e-con-boxed e-con e-child\" data-id=\"aecaec9\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;jet_parallax_layout_list&quot;:[]}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-d9d7a1a elementor-widget elementor-widget-text-editor\" data-id=\"d9d7a1a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p>Autoclave tape changes color when correct sterilization temperatures are reached. It validates successful processing. Standard masking tape cannot withstand autoclave conditions and must not be used.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-19210\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"11\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-19210\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Why is sterilizing prions and resistant microbes difficult? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><i aria-hidden=\"true\" class=\"fas fa-minus\"><\/i><\/span>\n\t\t\t<span class='e-closed'><i aria-hidden=\"true\" class=\"fas fa-plus\"><\/i><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-19210\" class=\"elementor-element elementor-element-3a8b0e6 e-flex e-con-boxed e-con e-child\" data-id=\"3a8b0e6\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;jet_parallax_layout_list&quot;:[]}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-113b4bc elementor-widget elementor-widget-text-editor\" data-id=\"113b4bc\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p>Prions require significantly higher temperatures and much longer cycles than standard sterilization. Heated jackets and custom cycle settings are often necessary to ensure complete sterilization.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-3b3bedf elementor-widget elementor-widget-html\" data-id=\"3b3bedf\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"html.default\">\n\t\t\t\t\t<script type=\"application\/ld+json\">\r\n{\r\n  \"@context\": \"https:\/\/schema.org\",\r\n  \"@type\": \"BlogPosting\",\r\n  \"mainEntityOfPage\": {\r\n    \"@type\": \"WebPage\",\r\n    \"@id\": \"https:\/\/labspx.com\/sterilization-based-on-your-load-type\/\"\r\n  },\r\n  \"headline\": \"Sterilization based on your load type\",\r\n  \"description\": \"Choosing the right sterilization process starts with understanding your load type. Laboratory waste, liquids, glassware, porous materials, and high-risk biological loads all behave differently during sterilization, and therefore require specific cycles, temperatures, and handling methods.\",\r\n  \"image\": \"https:\/\/labspx.com\/wp-content\/uploads\/2026\/01\/Welcome-to-the-new-LabSPX-website-26.png\",  \r\n  \"author\": {\r\n    \"@type\": \"Organization\",\r\n    \"name\": \"LabSPX\",\r\n    \"url\": \"https:\/\/labspx.com\/\"\r\n  },  \r\n  \"publisher\": {\r\n    \"@type\": \"Organization\",\r\n    \"name\": \"LabSPX\",\r\n    \"logo\": {\r\n      \"@type\": \"ImageObject\",\r\n      \"url\": \"https:\/\/labspx.com\/wp-content\/uploads\/2025\/09\/LabSPX-RGB-icon.png\"\r\n    }\r\n  },\r\n  \"datePublished\": \"2026-01-29\",\r\n  \"dateModified\": \"2026-08-20\r\n}\r\n<\/script>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-cdc291d elementor-widget elementor-widget-html\" data-id=\"cdc291d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"html.default\">\n\t\t\t\t\t<script type=\"application\/ld+json\">\r\n{\r\n  \"@context\": \"https:\/\/schema.org\",\r\n  \"@type\": \"FAQPage\",\r\n  \"mainEntity\": [{\r\n    \"@type\": \"Question\",\r\n    \"name\": \"What is a fluid load?\",\r\n    \"acceptedAnswer\": {\r\n      \"@type\": \"Answer\",\r\n      \"text\": \"A fluid load consists of liquids used in laboratory environments, such as growth media, solutions, or chemicals, that require sterilization. Any non\u2011solid material that must be sterilized before use is considered a fluid load.\"\r\n    }\r\n  },{\r\n    \"@type\": \"Question\",\r\n    \"name\": \"Why do sterilization parameters vary for fluid loads?\",\r\n    \"acceptedAnswer\": {\r\n      \"@type\": \"Answer\",\r\n      \"text\": \"Different media types require different temperatures or exposure times. While many are sterilized at 121\u202f\u00b0C for 15 minutes, others need different cycle parameters, so autoclaves must support a wide temperature range.\"\r\n    }\r\n  },{\r\n    \"@type\": \"Question\",\r\n    \"name\": \"What types of fluid discard require sterilization?\",\r\n    \"acceptedAnswer\": {\r\n      \"@type\": \"Answer\",\r\n      \"text\": \"Typical fluid discard includes used culture media, reagents, liquid specimens, cleaning solutions, and biological waste.\"\r\n    }\r\n  },{\r\n    \"@type\": \"Question\",\r\n    \"name\": \"How are sealed fluids sterilized?\",\r\n    \"acceptedAnswer\": {\r\n      \"@type\": \"Answer\",\r\n      \"text\": \"Sealed fluids are sterilized using air purging (freesteaming). Prolonged freesteaming is usually unnecessary. Higher temperatures than 121\u202f\u00b0C can shorten sterilization times, and cooling should be kept as short as possible to maintain product quality.\"\r\n    }\r\n  },{\r\n    \"@type\": \"Question\",\r\n    \"name\": \"Why is sterilizing mixed discard loads challenging?\",\r\n    \"acceptedAnswer\": {\r\n      \"@type\": \"Answer\",\r\n      \"text\": \"Because these loads often contain bags, plastics, and containers that trap air. This prevents effective steam penetration. Items may melt or collapse during the cycle, increasing the risk of air pockets.\"\r\n    }\r\n  },{\r\n    \"@type\": \"Question\",\r\n    \"name\": \"Are special autoclaves needed for high\u2011risk waste\",\r\n    \"acceptedAnswer\": {\r\n      \"@type\": \"Answer\",\r\n      \"text\": \"Yes. For BSL\u20113 applications, autoclaves with HEPA filtration, vacuum systems, or Category III compliance are recommended.\"\r\n    }\r\n  },{\r\n    \"@type\": \"Question\",\r\n    \"name\": \"Which types of glassware can be autoclaved?\",\r\n    \"acceptedAnswer\": {\r\n      \"@type\": \"Answer\",\r\n      \"text\": \"Common autoclaved glassware includes flasks, beakers, test tubes, cylinders, and watch glasses. Borosilicate and quartz glassware are recommended because they tolerate high temperatures and pressure.\"\r\n    }\r\n  },{\r\n    \"@type\": \"Question\",\r\n    \"name\": \"How are glassware and instruments dried after sterilization?\",\r\n    \"acceptedAnswer\": {\r\n      \"@type\": \"Answer\",\r\n      \"text\": \"Unwrapped instruments dry through heated air. Glassware may require specialized drying or post\u2011vacuum systems (benchtop units) or jacketed vessels (large autoclaves).\"\r\n    }\r\n  },{\r\n    \"@type\": \"Question\",\r\n    \"name\": \"What porous materials can be sterilized in an autoclave?\",\r\n    \"acceptedAnswer\": {\r\n      \"@type\": \"Answer\",\r\n      \"text\": \"Textiles such as gowns, wraps, bedding, and reusable instrument packs.\"\r\n    }\r\n  },{\r\n    \"@type\": \"Question\",\r\n    \"name\": \"Why is autoclave tape important?\",\r\n    \"acceptedAnswer\": {\r\n      \"@type\": \"Answer\",\r\n      \"text\": \"Autoclave tape changes color when correct sterilization temperatures are reached. It validates successful processing. Standard masking tape cannot withstand autoclave conditions and must not be used.\"\r\n    }\r\n  },{\r\n    \"@type\": \"Question\",\r\n    \"name\": \"Why is sterilizing prions and resistant microbes difficult?\",\r\n    \"acceptedAnswer\": {\r\n      \"@type\": \"Answer\",\r\n      \"text\": \"Prions require significantly higher temperatures and much longer cycles than standard sterilization. Heated jackets and custom cycle settings are often necessary to ensure complete sterilization.\"\r\n    }\r\n  }]\r\n}\r\n<\/script>\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<\/div><\/div>","protected":false},"excerpt":{"rendered":"<p>Which sterilization method fits your load type? Choosing the right sterilization process starts with understanding your load type. Laboratory waste, liquids, glassware, porous materials, and high-risk biological loads all behave differently during sterilization, and therefore require specific cycles, temperatures, and handling methods. This guide covers the most common load types and what to consider for [&hellip;]<\/p>\n","protected":false},"author":5,"featured_media":2972,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[1],"tags":[],"class_list":["post-2860","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-uncategorized"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.8 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Sterilization based on your load type | LabSPX<\/title>\n<meta name=\"description\" content=\"Choosing the right sterilization process starts with understanding your load type. Read our blogpost for more tips.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/labspx.com\/de\/sterilisation-auf-der-grundlage-ihrer-beladungsart\/\" \/>\n<meta property=\"og:locale\" content=\"de_DE\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Sterilization based on your load type | LabSPX\" \/>\n<meta property=\"og:description\" content=\"Choosing the right sterilization process starts with understanding your load type. Read our blogpost for more tips.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/labspx.com\/de\/sterilisation-auf-der-grundlage-ihrer-beladungsart\/\" \/>\n<meta property=\"og:site_name\" content=\"LabSPX\" \/>\n<meta property=\"article:published_time\" content=\"2026-01-29T12:50:44+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-08-21T09:16:16+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/labspx.com\/wp-content\/uploads\/2026\/01\/Welcome-to-the-new-LabSPX-website-26.png\" \/>\n\t<meta property=\"og:image:width\" content=\"1362\" \/>\n\t<meta property=\"og:image:height\" content=\"1022\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"author\" content=\"Charlotte\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Verfasst von\" \/>\n\t<meta name=\"twitter:data1\" content=\"Charlotte\" \/>\n\t<meta name=\"twitter:label2\" content=\"Gesch\u00e4tzte Lesezeit\" \/>\n\t<meta name=\"twitter:data2\" content=\"13\u00a0Minuten\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/labspx.com\\\/sterilization-based-on-your-load-type\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/labspx.com\\\/sterilization-based-on-your-load-type\\\/\"},\"author\":{\"name\":\"Charlotte\",\"@id\":\"https:\\\/\\\/labspx.com\\\/#\\\/schema\\\/person\\\/d1eab12834c8cf4c7e611bf70b2352c5\"},\"headline\":\"Sterilization based on your load type\",\"datePublished\":\"2026-01-29T12:50:44+00:00\",\"dateModified\":\"2026-08-21T09:16:16+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/labspx.com\\\/sterilization-based-on-your-load-type\\\/\"},\"wordCount\":2067,\"commentCount\":0,\"publisher\":{\"@id\":\"https:\\\/\\\/labspx.com\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/labspx.com\\\/sterilization-based-on-your-load-type\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/labspx.com\\\/wp-content\\\/uploads\\\/2026\\\/01\\\/Welcome-to-the-new-LabSPX-website-26.png\",\"articleSection\":[\"Uncategorized\"],\"inLanguage\":\"de\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/labspx.com\\\/sterilization-based-on-your-load-type\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/labspx.com\\\/sterilization-based-on-your-load-type\\\/\",\"url\":\"https:\\\/\\\/labspx.com\\\/sterilization-based-on-your-load-type\\\/\",\"name\":\"Sterilization based on your load type | LabSPX\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/labspx.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/labspx.com\\\/sterilization-based-on-your-load-type\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/labspx.com\\\/sterilization-based-on-your-load-type\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/labspx.com\\\/wp-content\\\/uploads\\\/2026\\\/01\\\/Welcome-to-the-new-LabSPX-website-26.png\",\"datePublished\":\"2026-01-29T12:50:44+00:00\",\"dateModified\":\"2026-08-21T09:16:16+00:00\",\"description\":\"Choosing the right sterilization process starts with understanding your load type. Read our blogpost for more tips.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/labspx.com\\\/sterilization-based-on-your-load-type\\\/#breadcrumb\"},\"inLanguage\":\"de\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/labspx.com\\\/sterilization-based-on-your-load-type\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"de\",\"@id\":\"https:\\\/\\\/labspx.com\\\/sterilization-based-on-your-load-type\\\/#primaryimage\",\"url\":\"https:\\\/\\\/labspx.com\\\/wp-content\\\/uploads\\\/2026\\\/01\\\/Welcome-to-the-new-LabSPX-website-26.png\",\"contentUrl\":\"https:\\\/\\\/labspx.com\\\/wp-content\\\/uploads\\\/2026\\\/01\\\/Welcome-to-the-new-LabSPX-website-26.png\",\"width\":1362,\"height\":1022,\"caption\":\"Sterilization based on your load type\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/labspx.com\\\/sterilization-based-on-your-load-type\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/labspx.com\\\/fr\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Sterilization based on your load type\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/labspx.com\\\/#website\",\"url\":\"https:\\\/\\\/labspx.com\\\/\",\"name\":\"LabSPX\",\"description\":\"Optimize your laboratory\",\"publisher\":{\"@id\":\"https:\\\/\\\/labspx.com\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/labspx.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"de\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/labspx.com\\\/#organization\",\"name\":\"LabSPX\",\"url\":\"https:\\\/\\\/labspx.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"de\",\"@id\":\"https:\\\/\\\/labspx.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/labspx.com\\\/wp-content\\\/uploads\\\/2025\\\/02\\\/favicon-labspx.jpg\",\"contentUrl\":\"https:\\\/\\\/labspx.com\\\/wp-content\\\/uploads\\\/2025\\\/02\\\/favicon-labspx.jpg\",\"width\":560,\"height\":560,\"caption\":\"LabSPX\"},\"image\":{\"@id\":\"https:\\\/\\\/labspx.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"}},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/labspx.com\\\/#\\\/schema\\\/person\\\/d1eab12834c8cf4c7e611bf70b2352c5\",\"name\":\"Charlotte\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"de\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/8b49ece6c2a67437d068dfcf2f6a045ff41bf4378888f6c5033f97907f3e23c0?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/8b49ece6c2a67437d068dfcf2f6a045ff41bf4378888f6c5033f97907f3e23c0?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/8b49ece6c2a67437d068dfcf2f6a045ff41bf4378888f6c5033f97907f3e23c0?s=96&d=mm&r=g\",\"caption\":\"Charlotte\"}}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Sterilisation je nach Beladungsart | LabSPX","description":"Die Wahl des richtigen Sterilisationsverfahrens beginnt damit, dass Sie den Typ Ihrer Beladung kennen. Lesen Sie unseren Blogpost f\u00fcr weitere Tipps.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/labspx.com\/de\/sterilisation-auf-der-grundlage-ihrer-beladungsart\/","og_locale":"de_DE","og_type":"article","og_title":"Sterilization based on your load type | LabSPX","og_description":"Choosing the right sterilization process starts with understanding your load type. Read our blogpost for more tips.","og_url":"https:\/\/labspx.com\/de\/sterilisation-auf-der-grundlage-ihrer-beladungsart\/","og_site_name":"LabSPX","article_published_time":"2026-01-29T12:50:44+00:00","article_modified_time":"2026-08-21T09:16:16+00:00","og_image":[{"width":1362,"height":1022,"url":"https:\/\/labspx.com\/wp-content\/uploads\/2026\/01\/Welcome-to-the-new-LabSPX-website-26.png","type":"image\/png"}],"author":"Charlotte","twitter_card":"summary_large_image","twitter_misc":{"Verfasst von":"Charlotte","Gesch\u00e4tzte Lesezeit":"13\u00a0Minuten"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/labspx.com\/sterilization-based-on-your-load-type\/#article","isPartOf":{"@id":"https:\/\/labspx.com\/sterilization-based-on-your-load-type\/"},"author":{"name":"Charlotte","@id":"https:\/\/labspx.com\/#\/schema\/person\/d1eab12834c8cf4c7e611bf70b2352c5"},"headline":"Sterilization based on your load type","datePublished":"2026-01-29T12:50:44+00:00","dateModified":"2026-08-21T09:16:16+00:00","mainEntityOfPage":{"@id":"https:\/\/labspx.com\/sterilization-based-on-your-load-type\/"},"wordCount":2067,"commentCount":0,"publisher":{"@id":"https:\/\/labspx.com\/#organization"},"image":{"@id":"https:\/\/labspx.com\/sterilization-based-on-your-load-type\/#primaryimage"},"thumbnailUrl":"https:\/\/labspx.com\/wp-content\/uploads\/2026\/01\/Welcome-to-the-new-LabSPX-website-26.png","articleSection":["Uncategorized"],"inLanguage":"de","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/labspx.com\/sterilization-based-on-your-load-type\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/labspx.com\/sterilization-based-on-your-load-type\/","url":"https:\/\/labspx.com\/sterilization-based-on-your-load-type\/","name":"Sterilisation je nach Beladungsart | LabSPX","isPartOf":{"@id":"https:\/\/labspx.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/labspx.com\/sterilization-based-on-your-load-type\/#primaryimage"},"image":{"@id":"https:\/\/labspx.com\/sterilization-based-on-your-load-type\/#primaryimage"},"thumbnailUrl":"https:\/\/labspx.com\/wp-content\/uploads\/2026\/01\/Welcome-to-the-new-LabSPX-website-26.png","datePublished":"2026-01-29T12:50:44+00:00","dateModified":"2026-08-21T09:16:16+00:00","description":"Die Wahl des richtigen Sterilisationsverfahrens beginnt damit, dass Sie den Typ Ihrer Beladung kennen. Lesen Sie unseren Blogpost f\u00fcr weitere Tipps.","breadcrumb":{"@id":"https:\/\/labspx.com\/sterilization-based-on-your-load-type\/#breadcrumb"},"inLanguage":"de","potentialAction":[{"@type":"ReadAction","target":["https:\/\/labspx.com\/sterilization-based-on-your-load-type\/"]}]},{"@type":"ImageObject","inLanguage":"de","@id":"https:\/\/labspx.com\/sterilization-based-on-your-load-type\/#primaryimage","url":"https:\/\/labspx.com\/wp-content\/uploads\/2026\/01\/Welcome-to-the-new-LabSPX-website-26.png","contentUrl":"https:\/\/labspx.com\/wp-content\/uploads\/2026\/01\/Welcome-to-the-new-LabSPX-website-26.png","width":1362,"height":1022,"caption":"Sterilization based on your load type"},{"@type":"BreadcrumbList","@id":"https:\/\/labspx.com\/sterilization-based-on-your-load-type\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/labspx.com\/fr\/"},{"@type":"ListItem","position":2,"name":"Sterilization based on your load type"}]},{"@type":"WebSite","@id":"https:\/\/labspx.com\/#website","url":"https:\/\/labspx.com\/","name":"LabSPX","description":"Optimieren Sie Ihr Labor","publisher":{"@id":"https:\/\/labspx.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/labspx.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"de"},{"@type":"Organization","@id":"https:\/\/labspx.com\/#organization","name":"LabSPX","url":"https:\/\/labspx.com\/","logo":{"@type":"ImageObject","inLanguage":"de","@id":"https:\/\/labspx.com\/#\/schema\/logo\/image\/","url":"https:\/\/labspx.com\/wp-content\/uploads\/2025\/02\/favicon-labspx.jpg","contentUrl":"https:\/\/labspx.com\/wp-content\/uploads\/2025\/02\/favicon-labspx.jpg","width":560,"height":560,"caption":"LabSPX"},"image":{"@id":"https:\/\/labspx.com\/#\/schema\/logo\/image\/"}},{"@type":"Person","@id":"https:\/\/labspx.com\/#\/schema\/person\/d1eab12834c8cf4c7e611bf70b2352c5","name":"Charlotte","image":{"@type":"ImageObject","inLanguage":"de","@id":"https:\/\/secure.gravatar.com\/avatar\/8b49ece6c2a67437d068dfcf2f6a045ff41bf4378888f6c5033f97907f3e23c0?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/8b49ece6c2a67437d068dfcf2f6a045ff41bf4378888f6c5033f97907f3e23c0?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/8b49ece6c2a67437d068dfcf2f6a045ff41bf4378888f6c5033f97907f3e23c0?s=96&d=mm&r=g","caption":"Charlotte"}}]}},"_links":{"self":[{"href":"https:\/\/labspx.com\/de\/wp-json\/wp\/v2\/posts\/2860","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/labspx.com\/de\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/labspx.com\/de\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/labspx.com\/de\/wp-json\/wp\/v2\/users\/5"}],"replies":[{"embeddable":true,"href":"https:\/\/labspx.com\/de\/wp-json\/wp\/v2\/comments?post=2860"}],"version-history":[{"count":61,"href":"https:\/\/labspx.com\/de\/wp-json\/wp\/v2\/posts\/2860\/revisions"}],"predecessor-version":[{"id":4801,"href":"https:\/\/labspx.com\/de\/wp-json\/wp\/v2\/posts\/2860\/revisions\/4801"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/labspx.com\/de\/wp-json\/wp\/v2\/media\/2972"}],"wp:attachment":[{"href":"https:\/\/labspx.com\/de\/wp-json\/wp\/v2\/media?parent=2860"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/labspx.com\/de\/wp-json\/wp\/v2\/categories?post=2860"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/labspx.com\/de\/wp-json\/wp\/v2\/tags?post=2860"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}