{"id":2469,"date":"2025-11-06T14:59:45","date_gmt":"2025-11-06T12:59:45","guid":{"rendered":"https:\/\/labspx.com\/?p=2469"},"modified":"2026-03-31T15:54:23","modified_gmt":"2026-03-31T13:54:23","slug":"tipps-fur-eine-bessere-zentrifugation","status":"publish","type":"post","link":"https:\/\/labspx.com\/de\/tips-for-better-centrifugation\/","title":{"rendered":"Tipps f\u00fcr eine bessere Zentrifugation"},"content":{"rendered":"<div class=\"product\"><div class=\"product\">\t\t<div data-elementor-type=\"wp-post\" data-elementor-id=\"2469\" class=\"elementor elementor-2469\" data-elementor-post-type=\"post\">\n\t\t\t\t<div class=\"elementor-element elementor-element-1545cb18 e-flex e-con-boxed e-con e-parent\" data-id=\"1545cb18\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;jet_parallax_layout_list&quot;:[]}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-3884d216 elementor-widget elementor-widget-text-editor\" data-id=\"3884d216\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t\n<h3 class=\"wp-block-heading\">How to prevent microcentrifuge tube lids from breaking during centrifugation?<\/h3>\n\n<p class=\"wp-block-paragraph\">When performing DNA cleanup procedures such as PCR cleanup or plasmid preparation, samples are often collected in 1.5 mL microcentrifuge tubes. Improper tube placement can lead to excessive lid tension, increasing the risk of breakage or sample contamination.<\/p>\n\n<p class=\"wp-block-paragraph\"><strong>Solution: position tubes in pairs<\/strong><\/p>\n\n<ul data-start=\"1112\" data-end=\"1264\">\n<li data-section-id=\"1bgyhs9\" data-start=\"1112\" data-end=\"1153\">Place tubes in pairs inside the rotor<\/li>\n<li data-section-id=\"1ij7xh4\" data-start=\"1154\" data-end=\"1205\">Ensure the lids are facing away from each other<\/li>\n<li data-section-id=\"1gpjz8z\" data-start=\"1206\" data-end=\"1264\">This reduces stress on the caps and improves stability<\/li>\n<\/ul>\n<p class=\"wp-block-paragraph\" data-start=\"1266\" data-end=\"1362\">This simple adjustment helps prevent damage and ensures a more secure fit during centrifugation.<\/p>\n\n<h3 class=\"wp-block-heading\">How do you properly balance a centrifuge?<\/h3>\n\n<p class=\"wp-block-paragraph\">When preparing samples for centrifugation, whether for DNA purification, PCR cleanup, or other lab protocols, it\u2019s not just about loading tubes and pressing \u201cstart.\u201d A well-balanced rotor is essential for both sample integrity and the longevity of your centrifuge.<\/p>\n\n<p class=\"wp-block-paragraph\" data-start=\"1415\" data-end=\"1508\">An unbalanced rotor can cause:<\/p>\n<ul data-start=\"1510\" data-end=\"1645\">\n<li data-section-id=\"1m80m0r\" data-start=\"1510\" data-end=\"1533\">Excessive vibration<\/li>\n<li data-section-id=\"wo3mas\" data-start=\"1534\" data-end=\"1548\">Loud noise<\/li>\n<li data-section-id=\"106af38\" data-start=\"1549\" data-end=\"1575\">Poor sample separation<\/li>\n<li data-section-id=\"oud62m\" data-start=\"1576\" data-end=\"1613\">Damage to the centrifuge or rotor<\/li>\n<li data-section-id=\"o5g70a\" data-start=\"1614\" data-end=\"1645\">Broken tubes or sample loss<\/li>\n<\/ul>\n<p data-start=\"1647\" data-end=\"1726\">In extreme cases, improper balancing can lead to rotor failure or safety risks.<\/p>\n\n<p class=\"wp-block-paragraph\"><strong>Solution: always balance mass and volume<\/strong><\/p>\n\n<ul class=\"wp-block-list\">\n<li>Always balance tubes by weight, not just by volume. Two tubes filled to the same volume may differ in mass if their solutions have different densities.<\/li>\n<li>Use a digital scale to check that your tube pairs match in mass as closely as possible.<\/li>\n\n<li>Place tubes symmetrically across from each other in the rotor.<\/li>\n<\/ul>\n<p>Examples:\u00a0<\/p>\n<ul>\n<li data-section-id=\"jorgwe\" data-start=\"1980\" data-end=\"2031\">With two tubes: place them opposite each other<\/li>\n<li data-section-id=\"1rm5b3r\" data-start=\"2032\" data-end=\"2073\">With four tubes: use a cross pattern<\/li>\n<li data-section-id=\"r7ga2p\" data-start=\"2074\" data-end=\"2141\">With multiple slots: distribute tubes evenly around the center<\/li>\n<\/ul>\n<p>What if you have an odd number of samples?\u00a0<\/p>\n<ul data-start=\"2191\" data-end=\"2339\">\n<li data-section-id=\"1qh33wg\" data-start=\"2191\" data-end=\"2227\">Prepare a balance tube (\u201cdummy\u201d)<\/li>\n<li data-section-id=\"183vplr\" data-start=\"2228\" data-end=\"2257\">Use the same type of tube<\/li>\n<li data-section-id=\"9yob2o\" data-start=\"2258\" data-end=\"2290\">Fill it with water or buffer<\/li>\n<li data-section-id=\"15r5f2f\" data-start=\"2291\" data-end=\"2339\">Match it to the mass of your heaviest sample<\/li>\n<\/ul>\n<p data-start=\"2341\" data-end=\"2423\">Even a single imbalance can affect performance, so precise balancing is essential.<\/p>\n\n<h3 class=\"wp-block-heading\">How to you select the right rotor and tubes for your centrifuge?<\/h3>\n\n<p class=\"wp-block-paragraph\">Choosing the correct rotor and tubes is essential for safe and efficient centrifugation. Using incompatible components can lead to poor separation, tube breakage, or even rotor failure.<\/p>\n\n<p class=\"wp-block-paragraph\"><strong>Solution: match rotor and tube specifications<\/strong><\/p>\n\n<ul class=\"wp-block-list\">\n<li><strong><em>Check rotor type and capacity:<\/em><\/strong> swing-out rotors are ideal for density gradient separations, while fixed-angle rotors work best for pelleting<\/li>\n\n<li><em><strong>Verify tube compatibility: <\/strong><\/em>ensure tubes are rated for the maximum speed and temperature of your centrifuge. Using tubes outside their specifications can cause cracks or leaks<\/li>\n\n<li><em><strong>Consider material and closure: <\/strong><\/em>polypropylene tubes are common for biological samples, while polycarbonate tubes handle higher speeds. Choose caps that seal securely under centrifugal force<\/li>\n\n<li><strong><em>Follow manufacturer guidelines:<\/em> <\/strong>always consult the centrifuge and rotor manuals for approved tube types and maximum load limits<\/li>\n<\/ul>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-25b53fe elementor-widget elementor-widget-heading\" data-id=\"25b53fe\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">FAQ<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-3e0d54d elementor-widget elementor-widget-n-accordion\" data-id=\"3e0d54d\" data-element_type=\"widget\" data-e-type=\"widget\" data-settings=\"{&quot;default_state&quot;:&quot;expanded&quot;,&quot;max_items_expended&quot;:&quot;one&quot;,&quot;n_accordion_animation_duration&quot;:{&quot;unit&quot;:&quot;ms&quot;,&quot;size&quot;:400,&quot;sizes&quot;:[]}}\" data-widget_type=\"nested-accordion.default\">\n\t\t\t\t\t\t\t<div class=\"e-n-accordion\" aria-label=\"Accordion. Open links with Enter or Space, close with Escape, and navigate with Arrow Keys\">\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-6500\" class=\"e-n-accordion-item\" open>\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"1\" tabindex=\"0\" aria-expanded=\"true\" aria-controls=\"e-n-accordion-item-6500\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Why do microcentrifuge tube lids sometimes break during centrifugation? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><i aria-hidden=\"true\" class=\"fas fa-minus\"><\/i><\/span>\n\t\t\t<span class='e-closed'><i aria-hidden=\"true\" class=\"fas fa-plus\"><\/i><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-6500\" class=\"elementor-element elementor-element-b3375e1 e-con-full e-flex e-con e-child\" data-id=\"b3375e1\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;jet_parallax_layout_list&quot;:[]}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-fe0e4a4 elementor-widget elementor-widget-text-editor\" data-id=\"fe0e4a4\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p>Lids often break because the tubes are positioned incorrectly in the rotor. When two tubes are placed too close or with their lids pressing toward each other, the tension on the caps increases during spinning. This added stress can cause cracking, popping open, or even contamination of your sample.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-6501\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"2\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-6501\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> How can you prevent tube lids from breaking during centrifugation? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><i aria-hidden=\"true\" class=\"fas fa-minus\"><\/i><\/span>\n\t\t\t<span class='e-closed'><i aria-hidden=\"true\" class=\"fas fa-plus\"><\/i><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-6501\" class=\"elementor-element elementor-element-f11bafc e-con-full e-flex e-con e-child\" data-id=\"f11bafc\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;jet_parallax_layout_list&quot;:[]}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-7959f18 elementor-widget elementor-widget-text-editor\" data-id=\"7959f18\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p>The simplest solution is to always place tubes in pairs and position them so that the lids face away from each other. This reduces mechanical stress on the caps and provides better stability throughout the run.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-6502\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"3\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-6502\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Why is balancing a centrifuge so important? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><i aria-hidden=\"true\" class=\"fas fa-minus\"><\/i><\/span>\n\t\t\t<span class='e-closed'><i aria-hidden=\"true\" class=\"fas fa-plus\"><\/i><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-6502\" class=\"elementor-element elementor-element-c92430e e-con-full e-flex e-con e-child\" data-id=\"c92430e\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;jet_parallax_layout_list&quot;:[]}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-2e5a9f7 elementor-widget elementor-widget-text-editor\" data-id=\"2e5a9f7\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p>Balancing ensures smooth operation and protects both your samples and the centrifuge. An unbalanced rotor creates strong vibrations that lead to noise, poor separation, broken tubes, shortened equipment lifespan, and in severe cases, rotor failure. Proper balance is essential for both safety and performance.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-6503\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"4\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-6503\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> How do you balance a centrifuge correctly? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><i aria-hidden=\"true\" class=\"fas fa-minus\"><\/i><\/span>\n\t\t\t<span class='e-closed'><i aria-hidden=\"true\" class=\"fas fa-plus\"><\/i><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-6503\" class=\"elementor-element elementor-element-100dcf7 e-con-full e-flex e-con e-child\" data-id=\"100dcf7\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;jet_parallax_layout_list&quot;:[]}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-cf6b8c7 elementor-widget elementor-widget-text-editor\" data-id=\"cf6b8c7\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p>Tubes must be balanced by mass, not only by volume. Two samples with identical volumes may not weigh the same if their solutions differ in density. To balance correctly, use a digital scale to match tube pairs as closely as possible, then place them symmetrically opposite each other inside the rotor.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-6504\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"5\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-6504\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> How do you choose the right rotor and tubes for your centrifuge? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><i aria-hidden=\"true\" class=\"fas fa-minus\"><\/i><\/span>\n\t\t\t<span class='e-closed'><i aria-hidden=\"true\" class=\"fas fa-plus\"><\/i><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-6504\" class=\"elementor-element elementor-element-0e8dde5 e-con-full e-flex e-con e-child\" data-id=\"0e8dde5\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;jet_parallax_layout_list&quot;:[]}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-9475aa9 elementor-widget elementor-widget-text-editor\" data-id=\"9475aa9\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p>Choosing the correct combination ensures safe operation and reliable separation. You should verify the rotor\u2019s design and capacity, confirm that your tubes are rated for the maximum speed and temperature you plan to use, and select tube materials and closures appropriate for your application. Always refer to the manufacturer\u2019s manuals to make sure the tubes are approved for your specific rotor.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-a53d2b3 elementor-widget elementor-widget-spacer\" data-id=\"a53d2b3\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"spacer.default\">\n\t\t\t\t\t\t\t<div class=\"elementor-spacer\">\n\t\t\t<div class=\"elementor-spacer-inner\"><\/div>\n\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-4ccc4fd elementor-widget elementor-widget-heading\" data-id=\"4ccc4fd\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Our centrifuges <\/h2>\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-9e98e7e e-grid e-con-boxed e-con e-parent\" data-id=\"9e98e7e\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;jet_parallax_layout_list&quot;:[]}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-eb6deae elementor-widget elementor-widget-image\" data-id=\"eb6deae\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"800\" height=\"800\" src=\"https:\/\/labspx.com\/wp-content\/uploads\/2025\/04\/kestrel-1024x1024.png\" class=\"attachment-large size-large wp-image-1361\" alt=\"small-capacity centrifuge\" srcset=\"https:\/\/labspx.com\/wp-content\/uploads\/2025\/04\/kestrel-1024x1024.png 1024w, https:\/\/labspx.com\/wp-content\/uploads\/2025\/04\/kestrel-300x300.png 300w, https:\/\/labspx.com\/wp-content\/uploads\/2025\/04\/kestrel-150x150.png 150w, https:\/\/labspx.com\/wp-content\/uploads\/2025\/04\/kestrel-768x768.png 768w, https:\/\/labspx.com\/wp-content\/uploads\/2025\/04\/kestrel-12x12.png 12w, https:\/\/labspx.com\/wp-content\/uploads\/2025\/04\/kestrel-600x600.png 600w, https:\/\/labspx.com\/wp-content\/uploads\/2025\/04\/kestrel-100x100.png 100w, https:\/\/labspx.com\/wp-content\/uploads\/2025\/04\/kestrel.png 1080w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-41d50b7 elementor-widget elementor-widget-image\" data-id=\"41d50b7\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"800\" height=\"800\" src=\"https:\/\/labspx.com\/wp-content\/uploads\/2025\/04\/Harrier-R-1024x1024.png\" class=\"attachment-large size-large wp-image-1342\" alt=\"Medium capacity refrigerated benchtop centrifuge\u00a0\" srcset=\"https:\/\/labspx.com\/wp-content\/uploads\/2025\/04\/Harrier-R-1024x1024.png 1024w, https:\/\/labspx.com\/wp-content\/uploads\/2025\/04\/Harrier-R-300x300.png 300w, https:\/\/labspx.com\/wp-content\/uploads\/2025\/04\/Harrier-R-150x150.png 150w, https:\/\/labspx.com\/wp-content\/uploads\/2025\/04\/Harrier-R-768x768.png 768w, https:\/\/labspx.com\/wp-content\/uploads\/2025\/04\/Harrier-R-12x12.png 12w, https:\/\/labspx.com\/wp-content\/uploads\/2025\/04\/Harrier-R-600x600.png 600w, https:\/\/labspx.com\/wp-content\/uploads\/2025\/04\/Harrier-R-100x100.png 100w, https:\/\/labspx.com\/wp-content\/uploads\/2025\/04\/Harrier-R.png 1080w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-17c6095 elementor-widget elementor-widget-image\" data-id=\"17c6095\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"800\" height=\"800\" src=\"https:\/\/labspx.com\/wp-content\/uploads\/2025\/04\/falcon-2-1024x1024.png\" class=\"attachment-large size-large wp-image-1344\" alt=\"Large capacity benchtop centrifuge\u00a0\" srcset=\"https:\/\/labspx.com\/wp-content\/uploads\/2025\/04\/falcon-2-1024x1024.png 1024w, https:\/\/labspx.com\/wp-content\/uploads\/2025\/04\/falcon-2-300x300.png 300w, https:\/\/labspx.com\/wp-content\/uploads\/2025\/04\/falcon-2-150x150.png 150w, https:\/\/labspx.com\/wp-content\/uploads\/2025\/04\/falcon-2-768x768.png 768w, https:\/\/labspx.com\/wp-content\/uploads\/2025\/04\/falcon-2-12x12.png 12w, https:\/\/labspx.com\/wp-content\/uploads\/2025\/04\/falcon-2-600x600.png 600w, https:\/\/labspx.com\/wp-content\/uploads\/2025\/04\/falcon-2-100x100.png 100w, https:\/\/labspx.com\/wp-content\/uploads\/2025\/04\/falcon-2.png 1080w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-00a4472 elementor-widget elementor-widget-text-editor\" data-id=\"00a4472\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p style=\"text-align: center;\"><strong>Microcentrifuge Kestrel<\/strong><\/p>\n<div class=\"elementor-element elementor-element-ea60830 elementor-widget elementor-widget-jet-listing-dynamic-field\" data-id=\"ea60830\" data-element_type=\"widget\" data-widget_type=\"jet-listing-dynamic-field.default\">\n<div class=\"elementor-widget-container\">\n<div class=\"jet-listing jet-listing-dynamic-field display-inline\">\n<div class=\"jet-listing-dynamic-field__inline-wrap\">\n<div class=\"jet-listing-dynamic-field__content\" style=\"text-align: center;\">Small-capacity centrifuges for medical environments<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-9373fdc elementor-widget elementor-widget-text-editor\" data-id=\"9373fdc\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<div class=\"elementor-element elementor-element-c9d0f4c elementor-widget elementor-widget-jet-listing-dynamic-field\" data-id=\"c9d0f4c\" data-element_type=\"widget\" data-widget_type=\"jet-listing-dynamic-field.default\">\n<div class=\"elementor-widget-container\">\n<div class=\"jet-listing jet-listing-dynamic-field display-inline\">\n<div class=\"jet-listing-dynamic-field__inline-wrap\">\n<div class=\"jet-listing-dynamic-field__content\" style=\"text-align: center;\"><strong>Harrier R benchtop centrifuge<\/strong><\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<div class=\"elementor-element elementor-element-ea60830 elementor-widget elementor-widget-jet-listing-dynamic-field\" data-id=\"ea60830\" data-element_type=\"widget\" data-widget_type=\"jet-listing-dynamic-field.default\">\n<div class=\"elementor-widget-container\">\n<div class=\"jet-listing jet-listing-dynamic-field display-inline\">\n<div class=\"jet-listing-dynamic-field__inline-wrap\">\n<div class=\"jet-listing-dynamic-field__content\" style=\"text-align: center;\">Designed for routine laboratory use with refrigeration system<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-7a466d1 elementor-widget elementor-widget-text-editor\" data-id=\"7a466d1\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p style=\"text-align: center;\"><strong>Falcon benchtop centrifuge<\/strong> Powerful induction drive, 3-litre capacity centrifuge without refrigeration<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-069667c elementor-align-center elementor-widget elementor-widget-button\" data-id=\"069667c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"button.default\">\n\t\t\t\t\t\t\t\t\t\t<a class=\"elementor-button elementor-button-link elementor-size-sm\" href=\"https:\/\/labspx.com\/shop\/microcentrifuge-kestrel-small-capacity\/\">\n\t\t\t\t\t\t<span class=\"elementor-button-content-wrapper\">\n\t\t\t\t\t\t\t\t\t<span class=\"elementor-button-text\">Read more <\/span>\n\t\t\t\t\t<\/span>\n\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-32b3e20 elementor-align-center elementor-widget elementor-widget-button\" data-id=\"32b3e20\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"button.default\">\n\t\t\t\t\t\t\t\t\t\t<a class=\"elementor-button elementor-button-link elementor-size-sm\" href=\"https:\/\/labspx.com\/shop\/harrier-r-medium-capacity-benchtop-centrifuge\/\">\n\t\t\t\t\t\t<span class=\"elementor-button-content-wrapper\">\n\t\t\t\t\t\t\t\t\t<span class=\"elementor-button-text\">Read more <\/span>\n\t\t\t\t\t<\/span>\n\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-50c1a08 elementor-align-center elementor-widget elementor-widget-button\" data-id=\"50c1a08\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"button.default\">\n\t\t\t\t\t\t\t\t\t\t<a class=\"elementor-button elementor-button-link elementor-size-sm\" href=\"https:\/\/labspx.com\/shop\/falcon-large-capacity-benchtop-centrifuge\/\">\n\t\t\t\t\t\t<span class=\"elementor-button-content-wrapper\">\n\t\t\t\t\t\t\t\t\t<span class=\"elementor-button-text\">Read more <\/span>\n\t\t\t\t\t<\/span>\n\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-b1890ba e-grid e-con-boxed e-con e-parent\" data-id=\"b1890ba\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;jet_parallax_layout_list&quot;:[]}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-27836a0 elementor-widget elementor-widget-image\" data-id=\"27836a0\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"800\" height=\"800\" src=\"https:\/\/labspx.com\/wp-content\/uploads\/2025\/04\/red-line-3-1024x1024.png\" class=\"attachment-large size-large wp-image-1317\" alt=\"High-speed centrifuges\" srcset=\"https:\/\/labspx.com\/wp-content\/uploads\/2025\/04\/red-line-3-1024x1024.png 1024w, https:\/\/labspx.com\/wp-content\/uploads\/2025\/04\/red-line-3-300x300.png 300w, https:\/\/labspx.com\/wp-content\/uploads\/2025\/04\/red-line-3-150x150.png 150w, https:\/\/labspx.com\/wp-content\/uploads\/2025\/04\/red-line-3-768x768.png 768w, https:\/\/labspx.com\/wp-content\/uploads\/2025\/04\/red-line-3-12x12.png 12w, https:\/\/labspx.com\/wp-content\/uploads\/2025\/04\/red-line-3-600x600.png 600w, https:\/\/labspx.com\/wp-content\/uploads\/2025\/04\/red-line-3-100x100.png 100w, https:\/\/labspx.com\/wp-content\/uploads\/2025\/04\/red-line-3.png 1080w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-eac972f elementor-widget elementor-widget-image\" data-id=\"eac972f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"800\" height=\"800\" src=\"https:\/\/labspx.com\/wp-content\/uploads\/2026\/01\/Blueforce-1024x1024.webp\" class=\"attachment-large size-large wp-image-2844\" alt=\"High-capacity, floor-standing centrifuge\" srcset=\"https:\/\/labspx.com\/wp-content\/uploads\/2026\/01\/Blueforce-1024x1024.webp 1024w, https:\/\/labspx.com\/wp-content\/uploads\/2026\/01\/Blueforce-300x300.webp 300w, https:\/\/labspx.com\/wp-content\/uploads\/2026\/01\/Blueforce-150x150.webp 150w, https:\/\/labspx.com\/wp-content\/uploads\/2026\/01\/Blueforce-768x768.webp 768w, https:\/\/labspx.com\/wp-content\/uploads\/2026\/01\/Blueforce-12x12.webp 12w, https:\/\/labspx.com\/wp-content\/uploads\/2026\/01\/Blueforce-600x600.webp 600w, https:\/\/labspx.com\/wp-content\/uploads\/2026\/01\/Blueforce-100x100.webp 100w, https:\/\/labspx.com\/wp-content\/uploads\/2026\/01\/Blueforce.webp 1080w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-5aec4f2 elementor-widget elementor-widget-image\" data-id=\"5aec4f2\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"800\" height=\"800\" src=\"https:\/\/labspx.com\/wp-content\/uploads\/2025\/04\/micro-centaur-r-1024x1024.png\" class=\"attachment-large size-large wp-image-1354\" alt=\"Refrigerated benchtop microcentrifuge\u00a0\" srcset=\"https:\/\/labspx.com\/wp-content\/uploads\/2025\/04\/micro-centaur-r-1024x1024.png 1024w, https:\/\/labspx.com\/wp-content\/uploads\/2025\/04\/micro-centaur-r-300x300.png 300w, https:\/\/labspx.com\/wp-content\/uploads\/2025\/04\/micro-centaur-r-150x150.png 150w, https:\/\/labspx.com\/wp-content\/uploads\/2025\/04\/micro-centaur-r-768x768.png 768w, https:\/\/labspx.com\/wp-content\/uploads\/2025\/04\/micro-centaur-r-12x12.png 12w, https:\/\/labspx.com\/wp-content\/uploads\/2025\/04\/micro-centaur-r-600x600.png 600w, https:\/\/labspx.com\/wp-content\/uploads\/2025\/04\/micro-centaur-r-100x100.png 100w, https:\/\/labspx.com\/wp-content\/uploads\/2025\/04\/micro-centaur-r.png 1080w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-7e2ef19 elementor-widget elementor-widget-text-editor\" data-id=\"7e2ef19\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p style=\"text-align: center;\"><strong>High-speed centrifuges\u00a0<\/strong><\/p>\n<div class=\"elementor-element elementor-element-ea60830 elementor-widget elementor-widget-jet-listing-dynamic-field\" data-id=\"ea60830\" data-element_type=\"widget\" data-widget_type=\"jet-listing-dynamic-field.default\">\n<div class=\"elementor-widget-container\">\n<div class=\"jet-listing jet-listing-dynamic-field display-inline\">\n<div class=\"jet-listing-dynamic-field__inline-wrap\">\n<div class=\"jet-listing-dynamic-field__content\" style=\"text-align: center;\">Red-line high-speed tabletop and floor standing centrifuges<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-6c8de49 elementor-widget elementor-widget-text-editor\" data-id=\"6c8de49\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<div class=\"elementor-element elementor-element-c9d0f4c elementor-widget elementor-widget-jet-listing-dynamic-field\" data-id=\"c9d0f4c\" data-element_type=\"widget\" data-widget_type=\"jet-listing-dynamic-field.default\">\n<div class=\"elementor-widget-container\">\n<div class=\"jet-listing jet-listing-dynamic-field display-inline\">\n<div class=\"jet-listing-dynamic-field__inline-wrap\">\n<div class=\"jet-listing-dynamic-field__content\" style=\"text-align: center;\"><strong>BlueForce 12L R\u00a0<\/strong><\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<div class=\"elementor-element elementor-element-ea60830 elementor-widget elementor-widget-jet-listing-dynamic-field\" data-id=\"ea60830\" data-element_type=\"widget\" data-widget_type=\"jet-listing-dynamic-field.default\">\n<div class=\"elementor-widget-container\">\n<div class=\"jet-listing jet-listing-dynamic-field display-inline\">\n<div class=\"jet-listing-dynamic-field__inline-wrap\">\n<div class=\"jet-listing-dynamic-field__content\" style=\"text-align: center;\">The Cellsep 6\/720 R is a compact floor-standing refrigerated centrifuge<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b5c2ed4 elementor-widget elementor-widget-text-editor\" data-id=\"b5c2ed4\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<div class=\"elementor-element elementor-element-c9d0f4c elementor-widget elementor-widget-jet-listing-dynamic-field\" data-id=\"c9d0f4c\" data-element_type=\"widget\" data-widget_type=\"jet-listing-dynamic-field.default\">\n<div class=\"elementor-widget-container\">\n<div class=\"jet-listing jet-listing-dynamic-field display-inline\">\n<div class=\"jet-listing-dynamic-field__inline-wrap\">\n<div class=\"jet-listing-dynamic-field__content\" style=\"text-align: center;\"><strong>Micro centaur P centrifuge<\/strong><\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<div class=\"elementor-element elementor-element-ea60830 elementor-widget elementor-widget-jet-listing-dynamic-field\" data-id=\"ea60830\" data-element_type=\"widget\" data-widget_type=\"jet-listing-dynamic-field.default\">\n<div class=\"elementor-widget-container\">\n<div class=\"jet-listing jet-listing-dynamic-field display-inline\">\n<div class=\"jet-listing-dynamic-field__inline-wrap\">\n<div class=\"jet-listing-dynamic-field__content\" style=\"text-align: center;\">Upgraded version of the original Micro Centaur with new features<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-9eff148 elementor-align-center elementor-widget elementor-widget-button\" data-id=\"9eff148\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"button.default\">\n\t\t\t\t\t\t\t\t\t\t<a class=\"elementor-button elementor-button-link elementor-size-sm\" href=\"https:\/\/labspx.com\/shop\/microcentrifuge-kestrel-small-capacity\/\">\n\t\t\t\t\t\t<span class=\"elementor-button-content-wrapper\">\n\t\t\t\t\t\t\t\t\t<span class=\"elementor-button-text\">Read more <\/span>\n\t\t\t\t\t<\/span>\n\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-2b6dd00 elementor-align-center elementor-widget elementor-widget-button\" data-id=\"2b6dd00\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"button.default\">\n\t\t\t\t\t\t\t\t\t\t<a class=\"elementor-button elementor-button-link elementor-size-sm\" href=\"https:\/\/labspx.com\/shop\/blueforce-12l-r-high-capacity-floor-standing-centrifuge\/\">\n\t\t\t\t\t\t<span class=\"elementor-button-content-wrapper\">\n\t\t\t\t\t\t\t\t\t<span class=\"elementor-button-text\">Read more <\/span>\n\t\t\t\t\t<\/span>\n\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-c8f17af elementor-align-center elementor-widget elementor-widget-button\" data-id=\"c8f17af\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"button.default\">\n\t\t\t\t\t\t\t\t\t\t<a class=\"elementor-button elementor-button-link elementor-size-sm\" href=\"https:\/\/labspx.com\/shop\/micro-centaur-r-small-capacity-centrifuge\/\">\n\t\t\t\t\t\t<span class=\"elementor-button-content-wrapper\">\n\t\t\t\t\t\t\t\t\t<span class=\"elementor-button-text\">Read more <\/span>\n\t\t\t\t\t<\/span>\n\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-84a9219 e-flex e-con-boxed e-con e-parent\" data-id=\"84a9219\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;jet_parallax_layout_list&quot;:[]}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-c9d6ebe elementor-widget elementor-widget-heading\" data-id=\"c9d6ebe\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">How can we help you <\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-9ebeb83 elementor-widget elementor-widget-text-editor\" data-id=\"9ebeb83\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p>Do you have another question? Fill out the form below and we\u2019ll be happy to assist you.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-5e8152b elementor-button-align-stretch elementor-widget elementor-widget-form\" data-id=\"5e8152b\" data-element_type=\"widget\" data-e-type=\"widget\" data-settings=\"{&quot;step_next_label&quot;:&quot;Next&quot;,&quot;step_previous_label&quot;:&quot;Previous&quot;,&quot;button_width&quot;:&quot;100&quot;,&quot;step_type&quot;:&quot;number_text&quot;,&quot;step_icon_shape&quot;:&quot;circle&quot;}\" data-widget_type=\"form.default\">\n\t\t\t\t\t\t\t<form class=\"elementor-form\" method=\"post\" name=\"New Form\" aria-label=\"New Form\">\n\t\t\t<input type=\"hidden\" name=\"post_id\" value=\"2469\"\/>\n\t\t\t<input type=\"hidden\" name=\"form_id\" value=\"5e8152b\"\/>\n\t\t\t<input type=\"hidden\" name=\"referer_title\" value=\"LabSPX\" \/>\n\n\t\t\t\n\t\t\t<div class=\"elementor-form-fields-wrapper elementor-labels-above\">\n\t\t\t\t\t\t\t\t<div class=\"elementor-field-type-text elementor-field-group elementor-column elementor-field-group-name elementor-col-100\">\n\t\t\t\t\t\t\t\t\t\t\t\t<label for=\"form-field-name\" class=\"elementor-field-label\">\n\t\t\t\t\t\t\t\tName\t\t\t\t\t\t\t<\/label>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t<input size=\"1\" type=\"text\" name=\"form_fields[name]\" id=\"form-field-name\" class=\"elementor-field elementor-size-sm  elementor-field-textual\" placeholder=\"Name\">\n\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t<div class=\"elementor-field-type-email elementor-field-group elementor-column elementor-field-group-email elementor-col-100 elementor-field-required\">\n\t\t\t\t\t\t\t\t\t\t\t\t<label for=\"form-field-email\" class=\"elementor-field-label\">\n\t\t\t\t\t\t\t\tEmail\t\t\t\t\t\t\t<\/label>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t<input size=\"1\" type=\"email\" name=\"form_fields[email]\" id=\"form-field-email\" class=\"elementor-field elementor-size-sm  elementor-field-textual\" placeholder=\"Email\" required=\"required\">\n\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t<div class=\"elementor-field-type-textarea elementor-field-group elementor-column elementor-field-group-message elementor-col-100\">\n\t\t\t\t\t\t\t\t\t\t\t\t<label for=\"form-field-message\" class=\"elementor-field-label\">\n\t\t\t\t\t\t\t\tMessage\t\t\t\t\t\t\t<\/label>\n\t\t\t\t\t\t<textarea class=\"elementor-field-textual elementor-field  elementor-size-sm\" name=\"form_fields[message]\" id=\"form-field-message\" rows=\"4\" placeholder=\"Message\"><\/textarea>\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t<div class=\"elementor-field-group elementor-column elementor-field-type-submit elementor-col-100 e-form__buttons\">\n\t\t\t\t\t<button class=\"elementor-button elementor-size-sm\" type=\"submit\">\n\t\t\t\t\t\t<span class=\"elementor-button-content-wrapper\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-button-text\">Send<\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t\t<\/span>\n\t\t\t\t\t<\/button>\n\t\t\t\t<\/div>\n\t\t\t<\/div>\n\t\t<\/form>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-7a477ab elementor-widget elementor-widget-html\" data-id=\"7a477ab\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"html.default\">\n\t\t\t\t\t<script type=\"application\/ld+json\">\r\n{\r\n  \"@context\": \"https:\/\/schema.org\",\r\n  \"@type\": \"BlogPosting\",\r\n  \"mainEntityOfPage\": {\r\n    \"@type\": \"WebPage\",\r\n    \"@id\": \"https:\/\/labspx.com\/tips-for-better-centrifugation\/\"\r\n  },\r\n  \"headline\": \"Tips for better centrifugation\",\r\n  \"description\": \"When performing DNA cleanup procedures such as PCR cleanup or plasmid preparation, samples are often collected in 1.5 mL microcentrifuge tubes. Improper tube placement can lead to excessive lid tension, increasing the risk of breakage or sample contamination.\",\r\n  \"image\": \"https:\/\/labspx.com\/wp-content\/uploads\/2025\/11\/Welcome-to-the-new-LabSPX-website-20.png\",  \r\n  \"author\": {\r\n    \"@type\": \"Organization\",\r\n    \"name\": \"LabSPX\",\r\n    \"url\": \"https:\/\/labspx.com\/\"\r\n  },  \r\n  \"publisher\": {\r\n    \"@type\": \"Organization\",\r\n    \"name\": \"LabSPX\",\r\n    \"logo\": {\r\n      \"@type\": \"ImageObject\",\r\n      \"url\": \"https:\/\/labspx.com\/wp-content\/uploads\/2025\/09\/cropped-LabSPX-RGB-icon.png\"\r\n    }\r\n  },\r\n  \"datePublished\": \"2025-11-06\",\r\n  \"dateModified\": \"2026-03-31\"\r\n}\r\n<\/script>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-9976bd0 elementor-widget elementor-widget-html\" data-id=\"9976bd0\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"html.default\">\n\t\t\t\t\t<script type=\"application\/ld+json\">\r\n{\r\n  \"@context\": \"https:\/\/schema.org\",\r\n  \"@type\": \"FAQPage\",\r\n  \"mainEntity\": [{\r\n    \"@type\": \"Question\",\r\n    \"name\": \"Why do microcentrifuge tube lids sometimes break during centrifugation?\",\r\n    \"acceptedAnswer\": {\r\n      \"@type\": \"Answer\",\r\n      \"text\": \"Lids often break because the tubes are positioned incorrectly in the rotor. When two tubes are placed too close or with their lids pressing toward each other, the tension on the caps increases during spinning. This added stress can cause cracking, popping open, or even contamination of your sample.\"\r\n    }\r\n  },{\r\n    \"@type\": \"Question\",\r\n    \"name\": \"How can you prevent tube lids from breaking during centrifugation?\",\r\n    \"acceptedAnswer\": {\r\n      \"@type\": \"Answer\",\r\n      \"text\": \"The simplest solution is to always place tubes in pairs and position them so that the lids face away from each other. This reduces mechanical stress on the caps and provides better stability throughout the run.\"\r\n    }\r\n  },{\r\n    \"@type\": \"Question\",\r\n    \"name\": \"Why is balancing a centrifuge so important?\",\r\n    \"acceptedAnswer\": {\r\n      \"@type\": \"Answer\",\r\n      \"text\": \"Balancing ensures smooth operation and protects both your samples and the centrifuge. An unbalanced rotor creates strong vibrations that lead to noise, poor separation, broken tubes, shortened equipment lifespan, and in severe cases, rotor failure. Proper balance is essential for both safety and performance.\"\r\n    }\r\n  },{\r\n    \"@type\": \"Question\",\r\n    \"name\": \"How do you balance a centrifuge correctly?\",\r\n    \"acceptedAnswer\": {\r\n      \"@type\": \"Answer\",\r\n      \"text\": \"Tubes must be balanced by mass, not only by volume. Two samples with identical volumes may not weigh the same if their solutions differ in density. To balance correctly, use a digital scale to match tube pairs as closely as possible, then place them symmetrically opposite each other inside the rotor.\"\r\n    }\r\n  },{\r\n    \"@type\": \"Question\",\r\n    \"name\": \"How do you choose the right rotor and tubes for your centrifuge?\",\r\n    \"acceptedAnswer\": {\r\n      \"@type\": \"Answer\",\r\n      \"text\": \"Choosing the correct combination ensures safe operation and reliable separation. You should verify the rotor\u2019s design and capacity, confirm that your tubes are rated for the maximum speed and temperature you plan to use, and select tube materials and closures appropriate for your application. Always refer to the manufacturer\u2019s manuals to make sure the tubes are approved for your specific rotor.\"\r\n    }\r\n  }]\r\n}\r\n<\/script>\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<\/div><\/div>","protected":false},"excerpt":{"rendered":"<p>How to prevent microcentrifuge tube lids from breaking during centrifugation? When performing DNA cleanup procedures such as PCR cleanup or plasmid preparation, samples are often collected in 1.5 mL microcentrifuge tubes. Improper tube placement can lead to excessive lid tension, increasing the risk of breakage or sample contamination. Solution: position tubes in pairs Place tubes [&hellip;]<\/p>\n","protected":false},"author":5,"featured_media":2470,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[1],"tags":[],"class_list":["post-2469","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-uncategorized"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.8 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Tips for better centrifugation | LabSPX<\/title>\n<meta name=\"description\" content=\"Discover essential centrifuge tips to improve safety and efficiency in the lab. Learn how to prevent tube lid breakage, and more!\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/labspx.com\/de\/tipps-fur-eine-bessere-zentrifugation\/\" \/>\n<meta property=\"og:locale\" content=\"de_DE\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Tips for better centrifugation | LabSPX\" \/>\n<meta property=\"og:description\" content=\"Discover essential centrifuge tips to improve safety and efficiency in the lab. Learn how to prevent tube lid breakage, and more!\" \/>\n<meta property=\"og:url\" content=\"https:\/\/labspx.com\/de\/tipps-fur-eine-bessere-zentrifugation\/\" \/>\n<meta property=\"og:site_name\" content=\"LabSPX\" \/>\n<meta property=\"article:published_time\" content=\"2025-11-06T12:59:45+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-03-31T13:54:23+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/labspx.com\/wp-content\/uploads\/2025\/11\/Welcome-to-the-new-LabSPX-website-20.png\" \/>\n\t<meta property=\"og:image:width\" content=\"1362\" \/>\n\t<meta property=\"og:image:height\" content=\"1022\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"author\" content=\"Charlotte\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Verfasst von\" \/>\n\t<meta name=\"twitter:data1\" content=\"Charlotte\" \/>\n\t<meta name=\"twitter:label2\" content=\"Gesch\u00e4tzte Lesezeit\" \/>\n\t<meta name=\"twitter:data2\" content=\"7\u00a0Minuten\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/labspx.com\\\/nl\\\/tips-voor-beter-centrifugeren\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/labspx.com\\\/nl\\\/tips-voor-beter-centrifugeren\\\/\"},\"author\":{\"name\":\"Charlotte\",\"@id\":\"https:\\\/\\\/labspx.com\\\/#\\\/schema\\\/person\\\/d1eab12834c8cf4c7e611bf70b2352c5\"},\"headline\":\"Tips for better centrifugation\",\"datePublished\":\"2025-11-06T12:59:45+00:00\",\"dateModified\":\"2026-03-31T13:54:23+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/labspx.com\\\/nl\\\/tips-voor-beter-centrifugeren\\\/\"},\"wordCount\":1077,\"commentCount\":0,\"publisher\":{\"@id\":\"https:\\\/\\\/labspx.com\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/labspx.com\\\/nl\\\/tips-voor-beter-centrifugeren\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/labspx.com\\\/wp-content\\\/uploads\\\/2025\\\/11\\\/Welcome-to-the-new-LabSPX-website-20.png\",\"articleSection\":[\"Uncategorized\"],\"inLanguage\":\"de\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/labspx.com\\\/nl\\\/tips-voor-beter-centrifugeren\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/labspx.com\\\/nl\\\/tips-voor-beter-centrifugeren\\\/\",\"url\":\"https:\\\/\\\/labspx.com\\\/nl\\\/tips-voor-beter-centrifugeren\\\/\",\"name\":\"Tips for better centrifugation | LabSPX\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/labspx.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/labspx.com\\\/nl\\\/tips-voor-beter-centrifugeren\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/labspx.com\\\/nl\\\/tips-voor-beter-centrifugeren\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/labspx.com\\\/wp-content\\\/uploads\\\/2025\\\/11\\\/Welcome-to-the-new-LabSPX-website-20.png\",\"datePublished\":\"2025-11-06T12:59:45+00:00\",\"dateModified\":\"2026-03-31T13:54:23+00:00\",\"description\":\"Discover essential centrifuge tips to improve safety and efficiency in the lab. Learn how to prevent tube lid breakage, and more!\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/labspx.com\\\/nl\\\/tips-voor-beter-centrifugeren\\\/#breadcrumb\"},\"inLanguage\":\"de\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/labspx.com\\\/nl\\\/tips-voor-beter-centrifugeren\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"de\",\"@id\":\"https:\\\/\\\/labspx.com\\\/nl\\\/tips-voor-beter-centrifugeren\\\/#primaryimage\",\"url\":\"https:\\\/\\\/labspx.com\\\/wp-content\\\/uploads\\\/2025\\\/11\\\/Welcome-to-the-new-LabSPX-website-20.png\",\"contentUrl\":\"https:\\\/\\\/labspx.com\\\/wp-content\\\/uploads\\\/2025\\\/11\\\/Welcome-to-the-new-LabSPX-website-20.png\",\"width\":1362,\"height\":1022,\"caption\":\"centrifugation\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/labspx.com\\\/nl\\\/tips-voor-beter-centrifugeren\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/labspx.com\\\/fr\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Tips for better centrifugation\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/labspx.com\\\/#website\",\"url\":\"https:\\\/\\\/labspx.com\\\/\",\"name\":\"LabSPX\",\"description\":\"Optimize your laboratory\",\"publisher\":{\"@id\":\"https:\\\/\\\/labspx.com\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/labspx.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"de\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/labspx.com\\\/#organization\",\"name\":\"LabSPX\",\"url\":\"https:\\\/\\\/labspx.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"de\",\"@id\":\"https:\\\/\\\/labspx.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/labspx.com\\\/wp-content\\\/uploads\\\/2025\\\/02\\\/favicon-labspx.jpg\",\"contentUrl\":\"https:\\\/\\\/labspx.com\\\/wp-content\\\/uploads\\\/2025\\\/02\\\/favicon-labspx.jpg\",\"width\":560,\"height\":560,\"caption\":\"LabSPX\"},\"image\":{\"@id\":\"https:\\\/\\\/labspx.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"}},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/labspx.com\\\/#\\\/schema\\\/person\\\/d1eab12834c8cf4c7e611bf70b2352c5\",\"name\":\"Charlotte\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"de\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/8b49ece6c2a67437d068dfcf2f6a045ff41bf4378888f6c5033f97907f3e23c0?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/8b49ece6c2a67437d068dfcf2f6a045ff41bf4378888f6c5033f97907f3e23c0?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/8b49ece6c2a67437d068dfcf2f6a045ff41bf4378888f6c5033f97907f3e23c0?s=96&d=mm&r=g\",\"caption\":\"Charlotte\"}}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Tipps f\u00fcr eine bessere Zentrifugation | LabSPX","description":"Entdecken Sie wichtige Tipps zur Zentrifugennutzung, f\u00fcr mehr Sicherheit und Effizienz im Labor. Erfahren Sie, wie Sie das Brechen von R\u00f6hrchendeckeln vermeiden und vieles mehr!","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/labspx.com\/de\/tipps-fur-eine-bessere-zentrifugation\/","og_locale":"de_DE","og_type":"article","og_title":"Tips for better centrifugation | LabSPX","og_description":"Discover essential centrifuge tips to improve safety and efficiency in the lab. Learn how to prevent tube lid breakage, and more!","og_url":"https:\/\/labspx.com\/de\/tipps-fur-eine-bessere-zentrifugation\/","og_site_name":"LabSPX","article_published_time":"2025-11-06T12:59:45+00:00","article_modified_time":"2026-03-31T13:54:23+00:00","og_image":[{"width":1362,"height":1022,"url":"https:\/\/labspx.com\/wp-content\/uploads\/2025\/11\/Welcome-to-the-new-LabSPX-website-20.png","type":"image\/png"}],"author":"Charlotte","twitter_card":"summary_large_image","twitter_misc":{"Verfasst von":"Charlotte","Gesch\u00e4tzte Lesezeit":"7\u00a0Minuten"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/labspx.com\/nl\/tips-voor-beter-centrifugeren\/#article","isPartOf":{"@id":"https:\/\/labspx.com\/nl\/tips-voor-beter-centrifugeren\/"},"author":{"name":"Charlotte","@id":"https:\/\/labspx.com\/#\/schema\/person\/d1eab12834c8cf4c7e611bf70b2352c5"},"headline":"Tips for better centrifugation","datePublished":"2025-11-06T12:59:45+00:00","dateModified":"2026-03-31T13:54:23+00:00","mainEntityOfPage":{"@id":"https:\/\/labspx.com\/nl\/tips-voor-beter-centrifugeren\/"},"wordCount":1077,"commentCount":0,"publisher":{"@id":"https:\/\/labspx.com\/#organization"},"image":{"@id":"https:\/\/labspx.com\/nl\/tips-voor-beter-centrifugeren\/#primaryimage"},"thumbnailUrl":"https:\/\/labspx.com\/wp-content\/uploads\/2025\/11\/Welcome-to-the-new-LabSPX-website-20.png","articleSection":["Uncategorized"],"inLanguage":"de","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/labspx.com\/nl\/tips-voor-beter-centrifugeren\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/labspx.com\/nl\/tips-voor-beter-centrifugeren\/","url":"https:\/\/labspx.com\/nl\/tips-voor-beter-centrifugeren\/","name":"Tipps f\u00fcr eine bessere Zentrifugation | LabSPX","isPartOf":{"@id":"https:\/\/labspx.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/labspx.com\/nl\/tips-voor-beter-centrifugeren\/#primaryimage"},"image":{"@id":"https:\/\/labspx.com\/nl\/tips-voor-beter-centrifugeren\/#primaryimage"},"thumbnailUrl":"https:\/\/labspx.com\/wp-content\/uploads\/2025\/11\/Welcome-to-the-new-LabSPX-website-20.png","datePublished":"2025-11-06T12:59:45+00:00","dateModified":"2026-03-31T13:54:23+00:00","description":"Entdecken Sie wichtige Tipps zur Zentrifugennutzung, f\u00fcr mehr Sicherheit und Effizienz im Labor. Erfahren Sie, wie Sie das Brechen von R\u00f6hrchendeckeln vermeiden und vieles mehr!","breadcrumb":{"@id":"https:\/\/labspx.com\/nl\/tips-voor-beter-centrifugeren\/#breadcrumb"},"inLanguage":"de","potentialAction":[{"@type":"ReadAction","target":["https:\/\/labspx.com\/nl\/tips-voor-beter-centrifugeren\/"]}]},{"@type":"ImageObject","inLanguage":"de","@id":"https:\/\/labspx.com\/nl\/tips-voor-beter-centrifugeren\/#primaryimage","url":"https:\/\/labspx.com\/wp-content\/uploads\/2025\/11\/Welcome-to-the-new-LabSPX-website-20.png","contentUrl":"https:\/\/labspx.com\/wp-content\/uploads\/2025\/11\/Welcome-to-the-new-LabSPX-website-20.png","width":1362,"height":1022,"caption":"centrifugation"},{"@type":"BreadcrumbList","@id":"https:\/\/labspx.com\/nl\/tips-voor-beter-centrifugeren\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/labspx.com\/fr\/"},{"@type":"ListItem","position":2,"name":"Tips for better centrifugation"}]},{"@type":"WebSite","@id":"https:\/\/labspx.com\/#website","url":"https:\/\/labspx.com\/","name":"LabSPX","description":"Optimieren Sie Ihr Labor","publisher":{"@id":"https:\/\/labspx.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/labspx.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"de"},{"@type":"Organization","@id":"https:\/\/labspx.com\/#organization","name":"LabSPX","url":"https:\/\/labspx.com\/","logo":{"@type":"ImageObject","inLanguage":"de","@id":"https:\/\/labspx.com\/#\/schema\/logo\/image\/","url":"https:\/\/labspx.com\/wp-content\/uploads\/2025\/02\/favicon-labspx.jpg","contentUrl":"https:\/\/labspx.com\/wp-content\/uploads\/2025\/02\/favicon-labspx.jpg","width":560,"height":560,"caption":"LabSPX"},"image":{"@id":"https:\/\/labspx.com\/#\/schema\/logo\/image\/"}},{"@type":"Person","@id":"https:\/\/labspx.com\/#\/schema\/person\/d1eab12834c8cf4c7e611bf70b2352c5","name":"Charlotte","image":{"@type":"ImageObject","inLanguage":"de","@id":"https:\/\/secure.gravatar.com\/avatar\/8b49ece6c2a67437d068dfcf2f6a045ff41bf4378888f6c5033f97907f3e23c0?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/8b49ece6c2a67437d068dfcf2f6a045ff41bf4378888f6c5033f97907f3e23c0?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/8b49ece6c2a67437d068dfcf2f6a045ff41bf4378888f6c5033f97907f3e23c0?s=96&d=mm&r=g","caption":"Charlotte"}}]}},"_links":{"self":[{"href":"https:\/\/labspx.com\/de\/wp-json\/wp\/v2\/posts\/2469","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/labspx.com\/de\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/labspx.com\/de\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/labspx.com\/de\/wp-json\/wp\/v2\/users\/5"}],"replies":[{"embeddable":true,"href":"https:\/\/labspx.com\/de\/wp-json\/wp\/v2\/comments?post=2469"}],"version-history":[{"count":20,"href":"https:\/\/labspx.com\/de\/wp-json\/wp\/v2\/posts\/2469\/revisions"}],"predecessor-version":[{"id":3354,"href":"https:\/\/labspx.com\/de\/wp-json\/wp\/v2\/posts\/2469\/revisions\/3354"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/labspx.com\/de\/wp-json\/wp\/v2\/media\/2470"}],"wp:attachment":[{"href":"https:\/\/labspx.com\/de\/wp-json\/wp\/v2\/media?parent=2469"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/labspx.com\/de\/wp-json\/wp\/v2\/categories?post=2469"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/labspx.com\/de\/wp-json\/wp\/v2\/tags?post=2469"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}